1. Measurement unit | Subject to be measured | Gasoline engine or general rotating body | |||
---|---|---|---|---|---|
Calculation method | Periodic calculation method | ||||
Measurement time | 1 s + input signal within 1 cycle time | ||||
[Engine rotation measurement] |
(IP-292 / 296 / 3000A / 3100, OM-1200 / 200, VP-1220 / 202) Input frequency range: 1 Hz to 1666.67 Hz Unit of measurement: r / min (rotational speed) Measurement range example: max 20000 r / min * * Maximum rotation speed is max 20000 r / min regardless of the number of pulse settings |
||||
[ Other than engine rotation measurement ] |
Signal waveform (when TTL is selected): Square wave Input level (when TTL is selected): Hi DC 4.5 to 5.5 V, Lo DC 0 to 0.5 V Input frequency range 3.33 Hz to 1666.67 Hz
|
||||
Measurement accuracy | Displayed value * × (± 0.02%) ± 1 count * The displayed value is the count value excluding the decimal point. The accuracy of the peripheral speed depends on the accuracy of the rotation speed (r / min). |
||||
Overrange function | Overrange (ERROR mark) display when the measured value exceeds the display range | ||||
Rotation upper limit warning function | When the rotation speed exceeds the preset upper limit value, the upper limit warning (↑ mark) is displayed. | ||||
Trigger adjustment volume | Adjustable with the rotary volume on the right side of the main unit | ||||
2. Detector | [Engine rotation measurement] | IP-292 / 296 / 3000A / 3100 (sold separately) Option Detects current change caused by ignition of ignition coil of gasoline engine OM-1200 / 200 (sold separately) Option Electromagnetic from ignition coil of gasoline engine or magnet rotation shaft of magnet ignition method Detects leakage magnetic flux using the induction method VP-1220 / 202 (sold separately) Detects vibration of optional 4-cylinder engine Note) It may not be detected normally depending on the type of engine and rotating body. |
|||
[ Other than engine rotation measurement ] |
OM-1200 / 200 (sold separately) Optional motor leakage magnetic flux detection MP-9000 series (sold separately) Optional detection Electromagnetic rotation detection method using gears, etc. Note) It may not be detected normally depending on the type of engine and rotating body. |
||||
3. Display |
Number of display digits: 5 digits Character height: 10.2 mm |
||||
4. Measurement mode | MAX (peak hold) | Display the maximum value during measurement | |||
MIN (peak hold) | Display the minimum value during measurement | ||||
NORMAL | Show current measurements | ||||
Memory function | Up to 20 measured values can be stored when the memory switch is pressed. The same memory value is stored in the volatile memory, so it is retained even if the power supply is cut off. |
||||
5. Analog output section | [REVO] | Voltage range | 0 ~ FS / 0 ~ 1 V | ||
Conversion method | 10 bit D / A conversion method | ||||
Linearity | ± 1% of FS | ||||
Output update time | 50 ms + input signal within 1 cycle time * Please note that if the input frequency range is out of range, a delay of several seconds will occur. |
||||
Temperature stability | ± 0.05% of FS / ℃ (ZERO & SPAN) | ||||
Setting error | ± 0.5% of FS (factory setting error ZERO & SPAN) | ||||
Load resistance | 100 kΩ or more | ||||
Output connector | Super mini jack (φ2.5) | ||||
[SIG] | Output contents | Analog output for monitor after waveform shaping of sensor signal (before pulse waveform conversion) | |||
Load resistance | 100 kΩ or more | ||||
Output connector | Super mini jack (shared with φ 2.5 / REVO output) | ||||
6. Pulse output section | Output timing | 1 pulse output for each signal detection | |||
Output voltage | Hi level: 4.5 V or higher Lo level: 0.5 V or lower |
||||
Output logic | Positive logic pulse | ||||
Load resistance | 100 kΩ or more | ||||
Output connector |
Super mini jack (φ2.5) |
||||
7. General specifications | Power supply | 4 AAA batteries or dedicated AC adapter | |||
Continuous use time | Approximately 16 hours (when the backlight is off) Approximately 8 hours (when the backlight is on) (using alkaline batteries, at 20 ° C) |
||||
LOW battery display | Lights up at about 4.5 V (at 20 ° C) Due to temperature changes, it may light up even if the battery voltage is 4.5 V or higher. |
||||
Operating temperature limit | 0 ℃ ~ + 40 ℃ | ||||
Storage temperature range | -10 ℃ ~ + 50 ℃ | ||||
Operating humidity range | 35-85% RH (no condensation) | ||||
Storage humidity range | 35-85% RH (no condensation) | ||||
Quality | Approximately 230 g (main unit only / not including batteries) | ||||
External dimensions | 180.5 x 66.0 x 47.5 mm (main unit only) | ||||
8. Conformity standard | CE marking | EMC Directive 2014/30 / EU Standard EN61326-1 RoHs Directive 2011/65 / EU Standard EN50581 |
|||
accessories | AAA batteries x 4, carrying case, instruction manual x 1 |