It conforms to ISO 2178, ISO 2360, and ISO 2808. Automatic determination of ferrous / nonferrous metals of electromagnetic / eddy current dual-use film thickness gauges
High repeat accuracy. A stable number comes out. Measurement data can be downloaded to PC Publication of calibration documents
Measurement range: 10-2000 μm Resolution: 0.1 um / 1 um / 0.01 mm
product name | ||
---|---|---|
Dual film thickness meter MJ-TG77 |
According to ISO2178 and ISO2360. The definitive edition of the film thickness meter! Stability stability. Issuable of calibration document
Automatic detection of iron / non-ferrous of electromagnetic / eddy current type dual-use film thickness meter (automatic substrate identification) substrate.
"Backlight" and "Auto Power Off" function. 99 recordable, with
average function. There is PC output. Film thickness measurement range: 0-2000 μm (2 mm) Resolution: 0.1 μm / 1 μm (100 μm or more)
Final value, average value, maximum value, minimum value, total number of measurement points can be confirmed.
product name | ||
---|---|---|
Thickness Gauge Dual Type MJ-TG21 Integrated Type |
Automatic detection of iron / nonferrous metal of electromagnetic type / eddy current type dual use film thickness meter (automatic substrate identification) . Can issue calibration documents
ISO 2178 and ISO 2360 compliant. The definitive edition of the film thickness meter! Stability stability. This price is cheap with a probe!
"Backlight" and "Auto Power Off" function. 99 recordable, with
average function. There is PC output. Film thickness measurement range: 0-2000 μm (2 mm) Resolution: 0.1 μm / 1 μm (100 μm or more)
Final value, average value, maximum value, minimum value, total number of measurement points can be confirmed.
product name | ||
---|---|---|
Thickness Gauge Dual Type MJ-TG2C Separate Type |
Film thickness measurement range: 0 to 1000 μm (1 mm) Resolution: 1 μm Backlight or
trigger with “Auto power off” function Simple film thickness measurement is possible with one hand simply by pulling a trigger (
for steel, iron) Simple calibration It is possible to maintain accuracy.
product name | ||
---|---|---|
Gun type film thickness meter CHY-113 |
Automatic detection of iron / nonferrous metal of electromagnetic type / eddy current type dual use film thickness meter (automatic substrate identification) .
Film thickness measurement range: 0 to 1000 μm (1 mm) resolution: 1 μm Backlight or
triggerwith “Auto power off” function The film thickness can be measured with one hand simply by pulling a trigger. Max / min alarm value function
single mode, continuous Measurement mode Up to 255 memory functions (no external output) Simple calibration possible
product name | ||
---|---|---|
Gun type film thickness meter CHY-115 dual |
You can measure whether the substrate is iron or non-ferrous. The material that can be issued for the calibration document is identified and switched to the measurement mode automatically. Film thickness measurement range: 0-2000 μm Resolution: 0.1 μm (0 to 99 μm), 1.0 μm (100 to 2000 μm) printer or measuring stand, external output Various options such as cables
product name | ||
---|---|---|
Dual type film thickness meter LZ-990 [Kett Kett] |
Electromagnetic induction type: 0-2500 μm Eddy current type: 0-1200 μm Resolution: 0.1 μm / 1.0 μm Calibration document can be issued Dual type electromagnetic film thickness meter LE-373 capable of film thickness measurement on magnetic material and nonmagnetic metal Eddy current film thickness meter LH-373 equipped with both functions, suitable film thickness meter for field use with various materials and various films
product name | ||
---|---|---|
Dual type film thickness meter LZ-373 [Kett Kett] |
Electromagnetic induction type: 0-2500 μm resolution: 0.1 μm (0 to 99 μm), 1.0 μm (100 to 2000 μm) Issuable of calibration documents Measurement of coating thickness such as plating (except electrolytic nickel plating) and coating on magnetic material It is a film thickness meter.
Data can be transferred to a printer or computer, and equipped with 16 functions such as calibration curve memory, measurement data memory, upper / lower limit settings, and statistical processing. Various options such as printer, measurement stand, external output cable
product name | ||
---|---|---|
Electromagnetic film thickness meter LE-373 [Kett Kett] |
Printer built-in film thickness meter. Calibration documents can be issued The
thickness of plating (except electrolytic nickel plating), coating, lining, etc. applied on magnetic metal can be measured quickly and accurately without damaging the film. In addition, you can print out the measurement results on the fly.
product name | ||
---|---|---|
Kett electromagnetic film thickness meter LE-200J |
A portable film thickness meter that has both electromagnetic and eddy current functions and has a built-in printer. Quickly respond to different film thickness measurements on magnetic and nonmagnetic metals. It has statistical calculation function, calibration / memory function, limit setting function, etc. where average value, standard deviation, maximum value and minimum value can be obtained with one button. Possible to issue proofs
product name | ||
---|---|---|
Ketto Dual Type Thickness Gauge LZ-200J |
◆ Automatic identification and measurement of base metal. ◆ Measurement in the dark with back light is also possible. Issuable of calibration documents
Iron base: 0 to 2.5 mm Non-ferrous metal base: 0 to 2.0 mm ◆ With data output function to PC (Pro).
◆ FN type is single function, Pro type is high function. ◆ With measurement value and calibration curve memory function (Pro).
product name | ||
---|---|---|
Dual type film thickness meter SAMAC-FN | ||
Dual type film thickness meter SAMAC-PRO |
◆ Selection of connection probe is possible according to measurement useissue of calibration document
◆ Excellent grip feeling by slim body. ◆ Guide display of operation procedure on LCD screen. ◆ Easy operation with 4 keys.
product name | ||
---|---|---|
Sanko Denshi Film thickness meter SWT-9000 (body) + FN-325 (probe) set | ||
Sanko Denshi Film thickness meter SWT-9000 only |
product name | ||
---|---|---|
Probe (for iron) FE-2.5 for SWT-9000 series | ||
SWT probe (for iron) FE-2.5L | ||
Probe (for iron) FE-2.5LWA (for SWT) | ||
SWT probe (for iron) FE-10 | ||
SWT probe (for iron) FE-20 | ||
Probe for SWT (Non-ferrous) NFE-2.0 | ||
Probe for SWT (Non-ferrous) NFE-2.0L | ||
SWT Probe (Non-ferrous) NFE-0.6 | ||
Probe for SWT (Non-ferrous) NFE-8 | ||
Probe for SWT (for both iron and non-ferrous metals) FN-325 |
Probe compatible. Ability to issue sophisticated calibration documents such as memory, statistical calculation, data transfer, etc.
product name | ||
---|---|---|
Film thickness meter SWT-9200 main unit only (Sankou Electronics) |
Measure the thickness of the coating resin applied to protect the surface of the concrete Measure the thickness
of the coating on concrete. 0.5 to 6.0 mm The
latest ultrasonic technology measures nondestructively the film thickness of resin lining, waterproof sheet, thick paint, etc. which are surface-treated on the ground of concrete structure.
product name | ||
---|---|---|
Ultrasonic film thickness meter ULT-5000 [Sankou Electronics] |
Contact thickness gauge made of stainless steel. By pressing a section against the coating before drying (adhesive, architectural paint, color paint, varnish, etc.), it is possible to estimate and judge the thickness of the coating after drying from the adhered paint solids
Table: μm Unit Back: mil unit
product name | ||
---|---|---|
Hexagon wet film thickness meter MJ-CM80 |
Contact thickness gauge made of stainless steel. By pressing a section against the coating before drying (adhesive, architectural paint, color paint, varnish, etc.), it is possible to estimate and judge the thickness of the coating after drying from the adhered paint solids
Table: μm Unit Back: mil unit
product name | ||
---|---|---|
Comb-shaped wet film thickness meter MJ-CM20 |
It is most suitable for the measurement of paint film thickness such as paint, coating material and sealing material. Issuable
range of calibration document Measurement range: 0 to 5 mm ● Minimum display: When
pressing the top point 0.01 mm , the needle-like stylus penetrates the coating and stops at the substrate. This penetrating length is the thickness of the membrane.
product name | ||
---|---|---|
Film thickness meter dial depth gauge DM-264 |
It is a coating film observation instrument in which a cutter for coating film cutting and a 50x microscope (100 equal division scale) are integrated.
Possible to issue proofs
product name | ||
---|---|---|
Cut Type Dry Thickness Gauge 455 (Paint Inspection Gauge) |
A measuring instrument that measures coating film hardness using a pencil. Used for measurement of adhesion strength and hardness of coating film.
■ We cope with load of 500 g / 750 g / 1000 g
■ Design based on JIS K-5600 (pencil scratch test), JIS K-5400
product name | ||
---|---|---|
Pencil scratch hardness tester MJ-PHT |
Easy check of surface salinity concentration before painting on ships etc. Measurement cell can be
measured by magnetic force without contaminating the measurement surface of fixedcalibration documents . Measuring range: Water soluble salt, sodium chloride (NaCl)
0 to 199.9 mg / m 2, 0 to 1999 mg / m 2 (auto range). Electrical conductivity: 0 to 199.9 μS / cm, 0 to 1.999 mS / cm (Auto range) 0 to 50 ° C (Display range: 0 to 99.9 ° C)
product name | ||
---|---|---|
Surface salinity meter SNA-3000 |
Easy check of surface salinity concentration before painting on ships etc. Measurement cell fixed by magnetic force / measurable
range without polluting the measurement surface : Water-soluble salt content, issue of sodium chloride (NaCl) calibration document
0 to 199.9 mg / m2, 0 to 1999 mg / m2 (automatic range)
electric conduction Rate: 0 to 199.9 μS / cm, 0 to 1.999 mS / cm (Auto range)
0 to 50 ° C (Display range: 0 to 99.9 ° C)
product name | ||
---|---|---|
Surface salinity meter SSM-21P |