Ultrasonic thickness gauge measuring range of 0.01 mm increments : 1.0-200 mm Can issue calibration documents
Speed adjustment of 1,000 to 9,000 m / s possible. Simple operation
is also OK with the test block (test piece) attached to the easy operation, high performance, compact entry model main body. Automatic power off function
Handy type that measures thickness of metal, plastic, ceramic, epoxy, glass etc by ultrasonic
product name | frequency | range of measurement | diameter | ||
---|---|---|---|---|---|
Ultrasonic thickness gauge MJ-UT27 | 5 MHz | 2.0 to 200.0 mm | φ 10 mm | ||
Replacement Standard Transducer (for MJ-UT 27) |
Ultrasonic thickness gauge measuring range of 0.1 mm increments : 1.0 mm-100.0 mm calibration document available
No probe replacement / no paint through function.
Corrosion measurement of thickness measurement piping, iron plate etc easily without expertise and skill , and corrosion measurement inside iron, cast iron, aluminum, plastic etc. for thickness measurement of locations where measurement is difficult with vernier calipers or micrometer Measurement and diagnosis of wear from the outside
product name | ||
---|---|---|
Ultrasonic Thickness Gauge UM-1 |
High precision ultrasonic thickness gage with 0.01 mm increments Possible to issue calibration document for of corrosion proofing of
piping, iron plate etc., thickness measurement of places where measurement is difficult with vernier or micrometer,
iron, cast iron, aluminum, plastic Measurement and diagnosis of internal corrosion and wear from the outside, etc.
Standard probe D5008: 0.8 to 300.0 mm The probe is detachable and replaceable. It is recommended that you have several to suit your application.
product name | frequency | range of measurement | Operating temperature | ||
---|---|---|---|---|---|
Ultrasonic Thickness Gauge 2000C (with standard probe D5008) | 5.0 MHz | 0.8-300 mm | 0 to 60 ° C |
0.01 mm resolution. High precision ultrasonic thickness gauge . For field work practicality issue of the calibration document
Probe for standard D5008: With
5200 memory storage function of5 MHz / φ 11.0 mmmax. (No handwriting required) : Data transfer possible to PC (storage format : Txt) With USB cable
[difference from DC-2000C] 1) It is possible to record 5000 data. 2) The speed of sound of nine substances is registered in advance.
3) In the measurement mode, standard, minimum value, difference measurement, average value can be taken. / Set the upper and lower limit value, and display the limit (L display). In the no beep
/ difference measurement, a reference value can be set to display the difference measurement value.
product name | frequency | range of measurement | Operating temperature | ||
---|---|---|---|---|---|
Ultrasonic thickness gauge 2020C (with probe D5008) | 5 MHz | 0.8-300 mm | 0 to 60 ° C |
0.01 mm resolution. High precision ultrasonic thickness gauge . For practical use of field work Canissue of the calibration document
for thin Transducer for thin material D7006: 7.5 MHz / φ 9.0mmMeasuring range: 0.65-50.00 mm curvature ⌀ 15 × 1.2 mm or more
Up to 5200 memory storage function Attached (no handwriting required) : Data transferable to PC (storage format: txt) With USB cable
・ The speed of sound of nine substances can be registered and measured in advance. Standard, minimum, difference measurement, average can be taken.
・ The upper and lower limit values are also set, and limit display (L display). (No beep) ・ Setting of reference value in difference measurement enables display of difference measurement value
product name | ||
---|---|---|
Ultrasonic thickness gauge for thin objects 2020 C + D 7006 |
0.01 mm resolution. High precision ultrasonic thickness gauge . For field work practicality issue of the calibration document for ultra-thin objects D 7004: 10 MHz / φ 6.0 mm measuring range: 0.65-20.00 mm curvature: diameter 15 × 1.0 mm or more
up to 5200 cases With memory storage function (no handwriting required) : Data transfer to PC possible (storage format: txt) With USB cable
・ The speed of sound of nine substances can be registered / measured in advance. Standard, minimum value, difference measurement, average value can be taken.
・ The upper and lower limit values are also set, and limit display (L display). (No beep) ・ Setting of reference value in difference measurement enables display of difference measurement value
product name | ||
---|---|---|
Ultrasonic thickness gauge 2020 C + D 7004 for ultra thin materials / for curved parts |
0.01 mm resolution. High precision ultrasonic thickness gauge . Feasibility of field work Ball cylinder calibration documents can be issued
Probe for cast iron D 2012: 2 MHz / φ 17mmMeasuring range: 2-400 mm Curvature: With
a memory storage function ofdiameter 40 x 3.0 mm or moreup to 5200 cases ( No handwriting required) : Data transfer to PC possible (storage format: txt) With USB cable
・ The speed of sound of nine substances can be registered and measured in advance. Standard, minimum value, difference measurement, average value can be taken.
・ The upper and lower limit values are also set, and limit display (L display). (No beep) ・ Setting of reference value in difference measurement enables display of difference measurement value
product name | ||
---|---|---|
Ultrasonic thickness gauge 2020 C + D 2012 for cast iron (with memory function / 2 years warranty on main unit) |
Base material thickness can be measured from above the coating film
Ultrasonic thickness gauge equipped with echo and echo mode that can measure the thickness of the base material (base material) without removing the paint
◆ Measurement is possible without peeling off the coating material (* conditions apply)
High precision ultrasonic thickness gage 2mm on 0.01mm increments Possible to issue calibration documents Possible
to measure the thickness of the base material from above the paint and coating film. The thickness of the base material (base material) is measured without removing the paint
. The probe is replaceable. Memory function: 500 cases (PC output not possible) Ultrasonic thickness meter with echo and echo mode installed that can
reduce inspection time and cost such as 'time to remove coating film'
and measure only actual thickness
● Standard mode: PE ● Through paint mode: EE (also called echo echo mode · through coat mode)
product name | ||
---|---|---|
Ultrasonic Thickness Gauge Through Paint UM-2D |
Ultrasonic thickness gage calibration document issued at0.1 mm increments Possible
to measure the thickness of the base material from above the paint and coating film. It
is possible to reduce the inspection time and cost, such as measuring the thickness of the base material (base material) without taking off the paint, and 'time and effort to remove the coating film'. Echo echo mode that can measure only the actual thickness. On-board ultrasonic thickness gauge
● Standard mode: PE (pulse-echo) ● Through paint mode: EE (echo echo mode · through coat mode)
product name | ||
---|---|---|
Ultrasonic Thickness Gauge Through Paint UM-1D |
Double check with numbers and waveforms!proofing documents can be issued
A scope · B scope (A scan / B scan) display
■ Save 10000 data PC data output possible. No handwriting required.
Through paint can measure thickness of various materials with high precision : 3.00-25.0 mmStandard measurement range: 0.65-400 mm
■ Large easy-to-see color TFT display ■ The thickness of the base material can be measured from the top of the paint or coating film.
The thickness of the base material (base material) is measured without removing the paint ■ Pulse echo method (TE: standard, minimum, difference, average, limit mode)
■ Automatic zero calibration ■ Manual measurement mode ■ Transducer calibration function
product name | frequency | Measuring range (mm) | Through paint (mm) | ||
---|---|---|---|---|---|
Ultrasonic Thickness Gauge DC-4000 (waveform display, Japanese display, data logger) | 5 MHz | 1.44-200.00 | 3.00 to 25.00 |
Reliable ultrasonic thickness gauge that combines high performance with durability and easy operation. Calibration documents can be issued
• Easy-to-read semi-transmissive QVGA color display installed • Corrosion inspection using dual element probe
• Precise thickness measurement with various options • Waterproof and dustproof performance with IP67 standard
product name | |
---|---|
Ultrasonic thickness gauge 45MG (Olympus Olympus) |
Data memory, data communication function to personal computer, calibration document can be issued
difference display, upper and lower limit alarm function, statistical processing, versatile, sonic memory function
product name | ||
---|---|---|
Ultrasonic Thickness Gauge (with Memory Function) TI-120K [JFE Advantech] |
Ultrasonic Thickness Gauge TI-56K A successor to the ultrasonic thickness gauge TI-55K for thinobjects. Calibration documents can be issued
for thin
objects 0.8 to 80 mm, widely used as a general-purpose type ■ Ultrasonic thickness gauge 1/10 mm step thickness measurement possible Ultrasonic thickness gauge TI-56L Thick thickness ultrasonic thickness gauge TI-55L Successor model of.
For thick objects 1.5 to 250 mm, widely used as a general-purpose type ■ Ultrasonic thickness gauge 1/100 mm thickness measurement possible
product name | ||
---|---|---|
Ultrasonic Thickness Gauge for TI-56K Thin [JFE Advantech] 0.8-80 mm | ||
Ultrasonic Thickness Gauge for TI-56L Thick [JFE Advantech] 1.5 to 250 mm |
Ultrasonic thickness gauge for high precision 1/100 mm increments Thickness can be measured Can issue calibration documents
Wide range ultrasonic thickness for displaying 1/100 mm increments with excellent accuracy and portability, from thin to thick one Meter
efficiently support quality control and quality control of manufactured product
product name | ||
---|---|---|
High Accuracy Ultrasonic Thickness Gauge TI-66W [JFE Advantech] |
Ultrasonic Thickness Gauge TI-56H Ultrasonic thickness gauge used when the object to be measured at high temperature is high. Calibration
thicknesscan be issued.Ultrasonic Thickness Gauge TI-56F Ultrasonic Thickness Gauge You can use it to measure the thickness of castings such as iron and aluminum.
product name | ||
---|---|---|
Ultrasonic Thickness Gauge for TI-56H High Temperature [JFE Advantech] | ||
Ultrasonic Thickness Gauge for TI-56F Casting [JFE Advantech] |
Measurement range: 2.0 to 200.0 mm / B 0.8 to 100.0 mm Issuance of calibration documents
Resolution of 0.1 mm From
thickness inspection of metal corrosion to thickness measurement and inspection of a wide range of materials such as glass, plastics, ceramics, etc.
product name | range of measurement | ||
---|---|---|---|
Ultrasonic thickness gauge AD-3253 | 2.0 to 200.0 mm |
Measurement range: 0.8 to 200.0 mm (for the standard attached probe) Issue of calibration document
Resolution: 0.01 mm / 0.1 mm
Thickness gauge of a wide range of materials such as metal, glass, plastic, ceramic and epoxy.
product name | ||
---|---|---|
Ultrasonic Thickness Gauge AD-3255 [A & D] |
product name | ||
---|---|---|
Couplant co-medium (glycerin paste 400 ml) |
1mm, 3mm, 5mm, 10mm, 15mm, 20mm Step Specimens
Test specimens for calibration and performance check of thickness gauges. Possible to issue proofs
product name | ||
---|---|---|
Step test piece 6ST / 1-20 |
product name | ||
---|---|---|
Couplant contact medium high temperature (300 ml) |