Measurement target | Dental rotating body, textile rotating body, rotating body for high-speed machine tools * Part of the rotating body to be measured must be magnetized. |
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Corresponding detector | MP-5350 High-speed dedicated sensor (sold separately) | |||||||||||
Calculation method | Periodic calculation method | |||||||||||
Display | Liquid crystal display 5 digits (character height 10.2 mm), with backlight | |||||||||||
Measurement time | 50 ms + input signal within 10 cycle time | |||||||||||
Display update time | 1 s / 0.5 s switchable | |||||||||||
Unit of measurement | × 10 r / min | |||||||||||
Rotation speed measurement range |
* When the pulse number setting is "1" |
|||||||||||
Measurement accuracy | Displayed value x (± 0.02%) ± 1 count * Measurement accuracy for displayed value |
|||||||||||
Memory function | Measurement result Max. 20 Data is stored in non-volatile memory (recorded value is retained even when the power is turned off) | |||||||||||
Peak hold function | Maximum value (MAX), minimum value (MIN) | |||||||||||
Overrange display | Overrange ( ERROR mark) display when the measured value exceeds the display range | |||||||||||
Rotation upper limit warning function | When the rotation speed exceeds the preset upper limit value, the upper limit warning ( ↑ mark) is displayed. | |||||||||||
Trigger function | Adjust with the rotary volume on the right side of the main body | |||||||||||
Analog output | Output for rotation speed display value
Output voltage: 0 to 1 V / 0 to full scale (full scale can be set arbitrarily) (* Please note that if the rotation speed is out of the measurement range, a delay will occur for several seconds.) Temperature stability: ± 0.05% / Full scale / ° C (span & zero) |
|||||||||||
Monitor output | Analog output for monitoring sensor signals (using the above rotation speed analog output and switching) | |||||||||||
Pulse output | 1 pulse output for each signal detection
Output voltage: Hi +4.5 V or more, Lo +0.5 V or less |
|||||||||||
Operating temperature limit | 0 to + 40 ° C | |||||||||||
Storage temperature range | -10 ℃ ~ + 50 ℃ | |||||||||||
Operating humidity range | 35-85% RH (no condensation) | |||||||||||
Storage humidity range | 35-85% RH (no condensation) | |||||||||||
Power supply | AAA batteries (1.5 V) x 4 or dedicated AC adapter PB-7090 (optional) | |||||||||||
Battery life | Continuous use time: Approximately 13 hours (when the backlight is off), approximately 8 hours (when the backlight is on) (using alkaline batteries, at 20 ° C) |
|||||||||||
Battery warning display | A warning mark (LOW mark) is displayed when the battery voltage drops below approximately 4.4 V. | |||||||||||
External dimensions | 66 (W) x 189.5 (L) x 47.5 (D) mm | |||||||||||
Quality | Approximately 280 g (main unit only, including batteries) | |||||||||||
accessories |
|