เครื่องมือวัดอุตสาหกรรม l Measuring Instruments [10259]
คุณสมบัติการใช้งานเครื่องมือวัด l Featured Products [872]
รหัสสินค้า | SKU-07433 |
หมวดหมู่ | เครื่องทดสอบและอุปกรณ์ตรวจสอบ(Test and Inspection Equipment) |
ราคาปกติ | |
ลดเหลือ | 0.00 บาท |
สถานะสินค้า | Pre-Order |
ลงสินค้า | 9 มิ.ย. 2564 |
อัพเดทล่าสุด | 9 มิ.ย. 2564 |
คงเหลือ | 1 ชิ้น |
จำนวน | ชิ้น |
Applicable fluid | Uniform liquid water, hot water, distilled water, alcohol, etc. through which ultrasonic waves pass |
---|---|
Applicable piping inner diameter | ∅13mm ~ ∅6000mm (depending on the detector) ( The model number of the detector is required for estimation. ) |
Measured fluid temperature | -40 to + 200 ° C (depending on the detector) |
Measurement flow velocity range | 0 to ± 32 m / s (minimum ± 0.3 m / s) |
Measurement accuracy | ± 1.0% of rate (depending on diameter and flow velocity) |
Calculation / output cycle | 1 second |
Survey line | Propagation time difference formula (1 survey line) |
display | Backlit color graphic display (TFT LCD monitor) 240 * 320 dots |
Analog output signal | DC4-20mA (1 point) |
Analog input signal | DC4-20mA (2 points) or DC4-20mA + DC1-5V (1 point) |
Power-supply voltage | Built-in battery (12 hours continuous operation when fully charged) |
Converter structure | Dustproof and waterproof IP64 (without printer) |
Converter size | 210 x 120 x 65 mm (without printer) |
Transducer mass | About 1kg |
SD card | Data can be saved for about 2 years with 512MB. Up to 8GB |
Serial communication | Transmission data (instantaneous value, integrated value, etc. stored data on SD card) Use USB port Transmission distance: Maximum 3m |
function | Damping time constant (0 to 100 seconds) Instantaneous value display (10 digits) Various flow rate units can be set Integrated display (10 digits) Various flow rate units can be set Heat consumption calculation Self-diagnosis (battery low, received wave diagnosis from sensor) Flash memory (Measurement parameters of piping, fluid, sensor, etc.) Number of registered sites 32 zero adjustment (by set zero / clear zero) Graph display, waveform display Japanese, English, German, French, Spanish, Chinese display Forward / reverse flow rate measurement Low flow rate cut (0-5m / s) |
option | With printer: Screen hard copy, constant cycle printing, logger data printing Detector for measuring flow velocity distribution: Instantaneous value, average value flow velocity distribution display |