รหัสสินค้า | SKU-06748 |
หมวดหมู่ | เครื่องมือวัดด้านสิ่งแวดล้อม(Environmental Measuring Instrument) |
ราคาปกติ | |
ลดเหลือ | 0.00 บาท |
สถานะสินค้า | Pre-Order |
ลงสินค้า | 28 พ.ค. 2564 |
อัพเดทล่าสุด | 29 พ.ค. 2564 |
คงเหลือ | 1 ชิ้น |
จำนวน | ชิ้น |
Features of Satotech Solar Power System Checker IV Checker PROVA1011A
The solar power generation system checker PROVA1010 has been upgraded.
It is being used one after another for quality control in residential photovoltaic power generation system installation contractors and solar cell (solar panel) production lines.
DC current probe (Solar15) | Measurements, monitors and recordings for DC output of solar systems |
---|---|
AC power probe (Solar21) | Power conditioner AC output (2-phase, 3-phase) measurement, monitor, recording, conversion efficiency of maximum output power |
Photovoltaic system checker PROVA1011A + FLIRi3 (spot checker) set
sold separately: AC clamp meter + DC probe
A portable IV curve tracer that tests the performance of solar cells. You can easily measure cells and modules at the installation site and production line.
Ideal for quality control, product identification, solar cell power generation equipment confirmation, and solar cell module (panel) maintenance.
Satotech Solar Power System Checker IV Checker PROVA1011A Applications
Evaluate IV characteristics to evaluate the performance of solar cells
PROVA body (23 ± 5 ℃, irradiance ≧ 800W / m2, 4-wire measurement, maximum power 12,000W)
Display voltage | resolution | accuracy |
---|---|---|
1-1,000 V | 0.01V / 0.1V / 1V | ± 1% ± (1% ± 0.1V of Voc) |
* Accuracy is not guaranteed for measurements below around 10V
Voc: Open circuit voltage of solar panel or module If you want to measure only the voltage using the alligator clip, connect the V + clip and I + clip, and connect the V-clip and I. -Connect with a clip and convert 4 wires to 2 wires for measurement.
range | resolution | accuracy |
---|---|---|
0.1-12 A | 1 mA / 10 mA | ± 1% ± (1% ± 9mA of Isc) |
Isc: The short circuit current
circuit resistance of the solar panel or module is compensated during AUTO SCAN.
Isc is the current of the solar panel power cable measured with zero circuit resistance.
range | resolution | accuracy |
---|---|---|
0.1-12 A | 1 mA / 10 mA | ± 1% ± 9 mA |
No measurements will be taken if the current is above 12A.
The maximum power is 12,000W. If it exceeds 12,000W, the scan measurement will stop.
The minimum current for AUTO SCAN is 100 mA.
range | resolution | accuracy |
---|---|---|
0-2000 W / m2 | 1 W / m2 | ± 3% ± 20 dgts |
range | resolution | accuracy |
---|---|---|
-20 to 85 ° C | 0.1 ℃ | ± 1% ± 1 ℃ |
range | resolution | accuracy |
---|---|---|
DC 12 A | 1 mA / 10 mA | ± 2.0% ± 30 mA |
AC Watt (50 / 60Hz, PF = 0.6-1, CT = 1, voltage greater than AC4V, current greater than AC 1mA in the mA range, greater than AC 0.04A in the A range. Specifications apply for constant waveforms .)
Range (0-30 A) | resolution | Accuracy * 1 * 2 |
---|---|---|
0.050 – 9.999 W | 0.001 W | ± 2% ± 0.025 W |
10.00 – 99.99 W | 0.01 W | ± 2% ± 0.25 W |
100.0 – 999.9 W | 0.1 W | ± 2% ± 2.5 W |
1.000 – 9.999 KW | 0.001 KW | ± 2% ± 0.025 KW |
10.00 – 99.99 KW | 0.01 KW | ± 2% ± 0.25 KW |
100.0 – 999.9 KW | 0.1 KW | ± 2% ± 2.5 KW |
1000 – 9999 KW | 1 KW | ± 2% ± 25 KW |
When CT ≠ 1, the accuracy is equivalent to ± 2% in percentage. However, the power in the table (such as ± 0.025W) must be multiplied by the CT rate.
For example, ± 0.025W is ± 0.025W x CT rate.
If automatic Hz is selected, the AC voltage must be greater than or equal to 50V and the accuracy will have a phase angle error of 2 degrees.
Range (30-50A) | resolution | Accuracy * 3 * 4 |
---|---|---|
0.050 – 9.999 W | 0.001 W | ± 2% of VA ± 5 dgts |
10.00 – 99.99 W | 0.01 W | ± 2% of VA ± 5 dgts |
100.0 – 999.9 W | 0.1 W | ± 2% of VA ± 5 dgts |
1.000 – 9.999 KW | 0.001 KW | ± 2% of VA ± 5 dgts |
10.00 – 99.99 KW | 0.01 KW | ± 2% of VA ± 5 dgts |
100.0 – 999.9 KW | 0.1 KW | ± 2% of VA ± 5 dgts |
1000 – 9999 KW | 1 KW | ± 2% of VA ± 5 dgts |
CT rate range | From 1 to 250 |
---|---|
HP (horsepower) | 1H.P. = 746 W |
AC apparent power | (VA, 0.000 VA ~ 9999 KVA) VA = V rms x Arms |
AC reactive power | (VAR, 0.000 VA to 9999 KVA) VAR = √ (VA2-W2) |
AC active energy | (MWH, WH, KWH, 0 mWH ~ 999,999 KWH) WH = W * Time (in hours) |
Power coefficient (PF, AC V> 4V, AC mA> 1mA, AC A> 0.04 A, Watt> 50 dgts)
range | resolution | accuracy |
---|---|---|
0.000 to 1.000 | 0.001 | ± 0.04 |
Battery type | Rechargeable lithium battery (3400mAh) |
---|---|
Battery life | Approximately 400 linear scans (1000V to 1V, 0.1A to 12A), can be used continuously for approximately 8 hours |
Memory size | 512 Kbyte, 3980 Mod file, 320 REC file, 3980 PWR file |
AC adapter | Input: AC 100-240 V, Output: DC 15 V / 1-3 A |
Dimensions / weight | 257 (L) x 155 (W) x 57 (H) mm, 1,525 g |
Operating environment | 5-50 ℃, 85% RH (no condensation) |
Temperature coefficient | Full scale 0.1% / ℃ (<18 ℃ or> 28 ℃) |
accessories | Instruction manual (for main unit / software) Remote irradiance meter (lithium rechargeable battery type 1000mAh, with thermometer) CD-ROM, AC adapter, power cable, 2P-3P conversion cable, USB cable, test clip (red, black) , 4-wire to 2-wire conversion cable, 4-wire test cable, mounting bracket set, heat conductive gel, carrying bag |
Conductor size | Maximum approx. 23 mm |
---|---|
Battery type | AA batteries x 2 |
Range selection | Manual |
power consumption | About 10 Ma |
Low voltage display | Displayed with red LED |
Operating environment | -10 to 50 ° C, 85% RH or less (no condensation) |
Storage environment | -20 to 60 ° C, 75% RH or less (no condensation) |
Altitude | 2,000 m or less |
Size and weight | 183 mm (L) x 61.3 mm (W) x 35.6 mm (H), approx. 190 g (including batteries) |
accessories | Instruction manual, AA batteries x 2 |
Conductor size | Up to about 30 mm |
---|---|
Battery type | AA batteries x 2 |
display | 4 + 2 + 2 digit LCD |
display | Approximately 2 times / sec |
Range selection | Automatic |
Overload | "OL" display |
power consumption | Approximately 10 mA |
Low voltage display | With display |
Operating environment | -10 to 50 ° C, 85% RH or less (no condensation) |
Storage environment | -20 to 60 ° C, 75% RH or less (no condensation) |
Altitude | 2,000 m or less |
Size and weight | 210 mm (L) x 62 mm (W) x 35.6 mm (H), approx. 200 g (including batteries) |
accessories | Instruction manual, AA batteries x 2, test lead wire, test clip (red, black) |