Tetrahydrofuran Detection Tubes (20 to 800 ppm)Gastec Detection Tube No. 159 measures Tetrahydrofuran with a Range of 20-800 ppm.
- Measuring Range:
- 20 to 50 ppm
- 50 to 800 ppm
- Number of Pump Strokes: 2, 1
- Correction Factor: 0.4, 1
- Sampling Time: 3 minutes per pump stroke
- Detecting Limit: 2 ppm (2 pump strokes)
- Changes from Pale vermilion to Pale blue
- Corrections for temperature & humidity: Temperature correction is necessary
- 3 Year Shelf
- Reaction Principle: C4H8O + Cr6+ + H2SO4 → Cr3+
- Relative Standard Deviation: 15% (for 50 to 200 ppm), 10% (for 200 to 800 ppm)
- Store the tubes at cool and dark place.
- On-site measurements can be performed easily by anybody, anytime and anywhere, in a short time
- Easy-to-check direct reading possible due to calibrated scale directly printed on the tube
- An extensive measuring range can be obtained by adjusting the sampling volume
- In order to assure high precision, each production lot is tested and calibrated independently, Each detector tube has its own quality control number printed on the tube
- Long shelf-life with excellent long-term stability
TUBE NAME |
Tetrahydrofuran |
CHEMICAL FORMULA |
C4H8O |
MEASURING RANGE |
20-800ppm |
NO. TESTS PER BOX |
10 |
STORAGE |
Store tubes in a cool dark place |
TUBE NUMBER |
159 |