Methacrylonitrile Detection Tubes (0.2 to 32 ppm)Gastec Detection Tube No.192 measures Methacrylonitrile with a Range of 0.2 to 32 ppm.
- Measuring Range: 0.2 to 32 ppm
- Number of Pump Strokes: 4, 2, 1
- Correction Factor: 0.4, 1, 3.2
- Sampling Time: 2 minutes per pump stroke
- Detecting Limit: 0.1 ppm (4 pump strokes)
- Reaction Principle:
- CH2:C(CH3)CN + Cr6+ + H2SO4 → HCN
- 2HCN + HgCl2 → 2HCl
- HCl + Base → Chloride
- Corrections for temperature & humidity: Unnecessary
- Relative Standard Deviation: 10% (for 0.5 to 10 ppm)
- Changes from Yellow to Red
- 3 Year Shelf Life
- Store the tubes at cool and dark place.
- Comes in a Box of 5 pretubes and 5 detector tubes
- On-site measurements can be performed easily by anybody, anytime and anywhere, in a short time
- Easy-to-check direct reading possible due to calibrated scale directly printed on the tube
- An extensive measuring range can be obtained by adjusting the sampling volume
- In order to assure high precision, each production lot is tested and calibrated independently, Each detector tube has its own quality control number printed on the tube
- Long shelf-life with excellent long-term stability
TUBE NAME |
Methacrylonitrile |
CHEMICAL FORMULA |
CH2:C(CH3)CN |
MEASURING RANGE |
0.2-32ppm |
NO. TESTS PER BOX |
5 |
STORAGE |
Store tubes in a cool dark place |
TUBE NUMBER |
192 |