Benzene Detection Tubes (1 to 100 ppm)Gastec Detection Tube No. 121S measures Benzene With a Range of 1 to 100 ppm.
- Measuring Range:
- 1 to 20 ppm - 5 pump strokes
Correction factor: 1
- 20 to 100 ppm - 1 pump stroke
Correction factor: 5
- Sampling Time: 2 minutes per pump stroke
- Detecting Limit: 0.25 ppm (5 pump strokes)
- Color Change: White to Dark green
- Corrections for temperature & humidity: Unnecessary
- Relative Standard Deviation: 20% (for 1 o 5 ppm), 15% (for 5 to 20 ppm)
- Reaction Principe: C6H6 + I2O5 + H2S2O7 → I2
- 3 Year Shelf Life
- Store the tubes at cool and dark place
- Comes in a box of 5 detector tubes and 5 pre tubes
- On-site measurements can be performed easily by anybody, anytime and anywhere, in a short time
- Easy-to-check direct reading possible due to calibrated scale directly printed on the tube
- An extensive measuring range can be obtained by adjusting the sampling volume
- In order to assure high precision, each production lot is tested and calibrated independently, Each detector tube has its own quality control number printed on the tube
- Long shelf-life with excellent long-term stability
TUBE NAME |
Aromatic Hydrocarbon |
CHEMICAL FORMULA |
C6H6 |
MEASURING RANGE |
1-100ppm |
NO. TESTS PER BOX |
5 |
STORAGE |
Store tubes in a cool dark place |
TUBE NUMBER |
121SL |