Fluke’s 113 multimeter is designed for basic electrical tests and repairing most electrical problems. The 113 features Fluke’s unique VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage (up to 600A) or continuity, meaning you no longer have to carry out two separate tests. There is also improved accuracy with True-rms ac measurements on non-linear loads, a feature more commonly associated with higher priced multimeters.
The Fluke 113 also features a large back lit display for use on low light conditions, as well the ability to record signal fluctuations using the Min/Max function. Fluke have also added a diode test function along with capacitance and resistance measurement to make the 113 a toolbox essential.
Meets Measurement Category CAT III 600 V and Category IV 300 V standards for a higher level of safety.
VCHEK1 2 3 |
Range |
6.000 V / 60.00 V / 600.0 V |
Resolution |
0.001 V / 0.01 V/ 0.1 V |
|
Accuracy |
DC, 45 to 500 Hz: 2.0% + 3 |
|
Diode test4 |
Range |
2.000 V |
Resolution |
0.001 V |
|
Accuracy |
2.0% + 3 |
|
Continuity4 |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer |
Ω4 |
Range |
600.0 Ω / 6.000 kΩ / 60.00 kΩ |
Resolution |
0.1 Ω / 0.001 kΩ / 0.01 kΩ |
|
Accuracy |
0.9% + 2 / 0.9% + 1 / 0.9% + 1 |
|
Capacitance4 |
Range |
1000 nF / 10.00 μF / 100.0 μF / 9999 μF |
Resolution |
1 nF / 0.01 μF / 0.1 μF / 1 μF |
|
Accuracy |
1.9% + 2 |
|
1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. |
||
Specifications |
||
Maximum voltage between any terminal and earth ground |
600 V |
|
Display |
3 3/4-digits, 6000 counts, updates 4/sec |
|
Operating temperature |
-10°C to 50°C (14°F to 122°F) |
|
Storage temperature |
-40°C to 60°C (-22°F to 140°F) |
|
Temperature coefficient |
0.1 x (specified accuracy) / °C (< 18°C or > 28°C) |
|
Operating altitude |
2,000 m |
|
Storage altitude |
10,000 m |
|
Relative humidity |
95% to 30°C |
|
Battery type |
9 Volt Alkaline, IEC 6F22 |
|
Battery life |
Alkaline: 300 hours typical, without backlight |
|
Size (H x W x L) |
167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in) |
|
Weight |
13.0 oz (404 g) |
|
Safety |
IEC 61010-1: Pollution Degree 2 |
|
EMI regulations |
Complies with FCC Part 15, Class B |
|
Specifications |
||
VCHEK |
Input impedance (nominal) |
~3 kΩ < 300 pF |
VCHEK |
Common mode rejection ratio |
> 60 dB at DC, 50 or 60 Hz |
Ω |
Open circuit test voltage |
< 2.7 VDC |
Full scale voltage |
< 0.7 VDC |
|
Diode test |
Open circuit test voltage |
2.7 VDC |
Full scale voltage |
2.000 VDC |
|
Ω |
Short circuit current |
< 350 μA |
Diode test |
Short circuit current |
< 1.0 mA |