รหัสสินค้า | SKU-23327 |
หมวดหมู่ | เครื่องวัดวิเคราะห์แบบพกพา(Portable analyzers),Toa Dkk |
ราคาปกติ | |
ลดเหลือ | 0.00 บาท |
สถานะสินค้า | Pre-Order |
ลงสินค้า | 17 เม.ย. 2568 |
อัพเดทล่าสุด | 17 เม.ย. 2568 |
คงเหลือ | 1 ชิ้น |
จำนวน | ชิ้น |
JIS format (pH) |
JIS format I |
|
Measurement Act Model Approval Number (pH) |
No. SS191 |
|
Measurement method |
pH |
Glass electrode method |
ORP |
Platinum electrode method |
|
ion |
Ion electrode method |
|
temperature |
Thermistor resistor |
|
display |
Custom LCD (backlit) |
|
Measurement item / range |
pH |
pH0.00-pH14.00 |
mV (ORP) |
-2000-2000mV |
|
ion |
Depends on the sensor used |
|
temperature |
0.0-100.0 ℃ (Ion: Depends on the electrode) |
|
Display range |
pH |
pH-2.00-pH16.00 |
mV (ORP) |
-2200-2200mV |
|
ion |
~ 19.9Myug 0.0 / L |
|
temperature |
-5.0-110.0 ℃ |
|
Display resolution |
pH |
0.01 pH |
mV (ORP) |
1mV |
|
ion |
0.0 μg / L to 199 g / L (2 1/2 significant digits) |
|
temperature |
0.1 ℃ |
|
Repeatability (instrument body) |
pH |
Within ± 0.02 pH |
mV (ORP) |
± 2 mV |
|
ion |
± 0.5% FS |
|
temperature |
Within ± 0.2 ° C |
|
pH temperature compensation range |
ATC (Automatic Temperature Compensation): 0-100.0 ℃ |
|
pH calibration |
JIS pH standard solution, US standard solution, maximum 5-point calibration or custom standard solution, maximum 2-point calibration |
|
Temperature calibration |
1-point calibration |
|
Ion calibration |
Maximum 3-point calibration |
|
Guaranteed performance Temperature, humidity |
0-45 ℃ 20-90% or less (no condensation) |
|
Data memory |
1500 data |
|
Auto hold function |
○ (Stable judgment value: fixed) |
|
Clock function |
○ (Always display is valid during measurement) |
|
Calibration history creation function |
○ Latest 1 dose (“Cal memo” pH / ion electrode side can store 2 calibration data including the latest) |
|
Interval measurement * 1 |
○ (Setting interval: 1 second to 99 minutes 59 seconds or 2 minutes to 99 hours 59 minutes can be set arbitrarily) |
|
Auto power off |
○ (OFF / 10 minutes / 30 minutes / 60 minutes / 180 minutes / 360 minutes / 720 minutes can be set) |
|
Waterproof structure |
○ IP67 (disabled when electrode is not connected) * 1m, can be immersed for 30 minutes |
|
Power supply |
2 AA alkaline batteries / rechargeable nickel metal hydride batteries |
|
Battery life (estimated value) * Backlight off, option not connected |
About 2000 hours |
|
power consumption |
0.1VA (when using 3V battery) |
|
External dimensions (excluding protrusions) |
Approximately 70 (width) x 39 (height) x 188 (back) mm |
|
Body mass (including batteries) |
About 300g |