รหัสสินค้า | SKU-22846 |
หมวดหมู่ | เครื่องวัดคุณภาพน้ำแบบพกพา(Pocket Water Quality Meters),Horiba |
ราคาปกติ | |
ลดเหลือ | 0.00 บาท |
สถานะสินค้า | Pre-Order |
ลงสินค้า | 23 พ.ย. 2567 |
อัพเดทล่าสุด | 23 พ.ย. 2567 |
คงเหลือ | 1 ชิ้น |
จำนวน | ชิ้น |
![]() |
The Horiba U-50 series water quality meters are innovative units that will monitor,collect, display and store up to 11 parameters of ground and surface water simultaneously.
![]() |
![]() |
![]() |
U-50 Series Specifications |
U-51 |
U-52 |
U-52G |
U-53 |
U-53G |
U-54 |
U-54G |
||
Sensor Probe |
Measurement temperature |
-10 to 55℃ |
|
||||||
Maximum sensor diameter |
Approx. 96 mm |
|
|||||||
Probe length |
Approx. 340 mm |
|
|||||||
Cable length |
Standard: 2 m, option: 10, 30 m |
|
|||||||
Mass |
Approx. 1,800 g (Approx. 3.97 lbs) |
|
|||||||
Automatic calibration (uses pH4) |
● |
|
|||||||
Turbidity wiper |
─ |
─ |
─ |
● |
● |
─ |
─ |
|
|
Measurement depth |
Max. 30 m |
|
|||||||
Liquid contact part material (liquid end material) |
PPS, glass, SUS316L, SUS304, FKM, PEEK,Q, titanium, FEP membrane, POM |
|
|||||||
Water resistance |
JIS protection level 8 |
|
|||||||
Control Unit |
Outer dimensions |
115 (W) x 66 (D) x 283 (H) mm |
|
||||||
Mass |
Approx. 800 g (Approx. 1.76 lbs) |
|
|||||||
LCD |
320 x 240 liquid crystal display with backlight (black and white) |
|
|||||||
Data memory |
10.000 |
|
|||||||
Communication |
USB |
|
|||||||
Battery |
C batteries x 4 |
|
|||||||
Water resistance |
JIS protection level 7 (when sensor cable is fitted) |
|
|||||||
Battery Life |
Approx. 70 hours (without backlight) |
Approx. 500 measurements |
Approx. 70 hours (without backlight) |
|
|||||
Storage temperature |
-10 to 60℃ |
|
|||||||
Ambient temperature |
-5 to 45℃ |
|
|||||||
pH |
Measurement principle |
Glass electrode method |
|
||||||
Range |
pH 0 to 14 |
|
|||||||
Resolution |
0.01pH |
|
|||||||
Repeatability |
±0.05pH |
|
|||||||
Accuracy |
±0.1pH |
|
|||||||
Oxidation |
Measurement principle |
Platinum electrode method |
|
||||||
Range |
-2000 mV to +2000 mV |
|
|||||||
Resolution |
1 mV |
|
|||||||
Repeatability |
±5 mV |
|
|||||||
Accuracy |
±15 mV |
|
|||||||
Dissolved Oxygen |
Measurement principle |
Polarographic method |
|
||||||
Range |
0 to 50.0 mg/L |
|
|||||||
Resolution |
0.01 mg/L |
|
|||||||
Repeatability |
±0.1 mg/L |
|
|||||||
Accuracy |
0 to 20 mg/L: ±0.2 mg/L 20 to 50 mg/L: ±0.5 mg/L |
|
|||||||
Conductivity (COND) |
Measurement principle |
4 AC electrode method |
|
||||||
Range |
0 to 10 S/m (0 to 100 mS/cm) |
|
|||||||
Resolution |
0.000 to 0.999 mS/cm: 0.001 mS/cm 1.00 to 9.99 mS/cm: 0.01 mS/cm 10.0 to 99.9 mS/cm: 0.1 mS/cm |
|
|||||||
0.0 to 99.9 mS/m: 0.1 mS/m 0.100 to 0.999 S/m: 0.001 S/m 1.00 to 9.99 S/m : 0.01 S/m |
|
||||||||
Repeatability |
±0.05% F.S. |
|
|||||||
Accuracy |
*±1% F.S. (Median of two-point calibration) |
|
|||||||
Salinity |
Measurement principle |
Conductivity conversion |
|
||||||
Range |
0 to 70 PPT (permillage) |
|
|||||||
Resolution |
0.1 PPT |
|
|||||||
Repeatability |
±1 PPT |
|
|||||||
Accuracy |
±3 PPT |
|
|||||||
Total Dissolved Solid |
Measurement principle |
Conductivity conversion |
|
||||||
Range |
0 to 100 g/L |
|
|||||||
Resolution |
0.1% F.S. |
|
|||||||
Repeatability |
±2 g/L |
|
|||||||
Accuracy |
±5 g/L |
|
|||||||
Seawater specific |
Measurement principle |
Conductivity conversion |
|
||||||
Range |
0 to 50 σ t |
|
|||||||
Resolution |
0,1 σ t |
|
|||||||
Repeatability |
±2 σ t |
|
|||||||
Accuracy |
±5 σ t |
|
|||||||
Temperature |
Measurement principle |
Thermistor method |
|
||||||
Accuracy |
-10 to 55℃ |
|
|||||||
Range |
0.01℃ |
|
|||||||
Resolution |
*±0.10℃ (at calibration point) |
|
|||||||
Repeatability |
JIS class B platinum thermometer sensor (±0.3+0.005 | t |) |
|
|||||||
Turbidity (TURB) |
Measurement principle |
─ |
LED light source and 30°scattering method |
Tungsten lamp source and 90°scattering method |
LED light source and 90°scattering method |
|
|||
Range |
0 to 800 NTU |
0 to 1000 NTU |
0 to 1000 NTU |
|
|||||
Resolution |
0 to 99.9 NTU: 0.1 NTU 100 to 800 NTU: 1 NTU |
0 to 9.99 NTU: 0.01 NTU 10 to 99.9 NTU: 0.1 NTU |
0 to 0.99 NTU: 0.01 NTU 1 to 99.9 NTU: 0.1 NTU |
||||||
Repeatability |
*±5% (Reading) or ± 0.5 NTU whichever is greater |
±3% (Reading) or ±0.1 NTU whichever is greater |
±5% (Reading) or ± 0.5 NTU whichever is greater |
|
|||||
Accuracy |
±5% (Reading) or ±1 NTU whichever is greater |
0 to 10 NTU: ±0.5 NTU |
±5% (Reading) or ±1 NTU whichever is greater |
||||||
Water depth |
Measurement principle |
─ |
─ |
Pressure method |
Pressure method, only 10m and 30m product |
|
|||
Range |
0 to 30 m |
|
|||||||
Resolution |
0.05 m |
|
|||||||
Repeatability |
±1% F.S. |
|
|||||||
Accuracy |
±0.3 m |
|
|||||||
GPS |
12 channel parallel |
─ |
─ |
● |
─ |
● |
─ |
● |