รหัสสินค้า | SKU-22216 |
หมวดหมู่ | •เครื่องวัดอัตราการไหลแบบคลื่นเสียงความถี่สูง(Ultrasonic Flowmeter) |
ราคาปกติ | |
ลดเหลือ | 0.00 บาท |
สถานะสินค้า | Pre-Order |
ลงสินค้า | 5 ก.ค. 2567 |
อัพเดทล่าสุด | 5 ก.ค. 2567 |
คงเหลือ | 1 ชิ้น |
จำนวน | ชิ้น |
![]() |
The Portaflow-C flow meter is a non intrusive, non evasive clamp-on ultrasonic flow meter, which is suitable for measuring the flow and total flow of liquids in closed pipes. It is particularly useful where high accuracy is required and the flow meter needs to be installed without shutting down the process. The Portaflow C is the latest release in the Fuji Electric flow metering range and uses the Micro processor and digital signal processing technology to provide a compact, lightweight solution with accuracies that are better than 1% of Flow rate.
![]() |
|
![]() |
|
![]() |
Large capacity storage on SD memory card -Flow, velocity and total data can be stored in SD memory card (data logger function). Files are saved as csv files, directly compatible with MS-Excel software | |
Heat quantity measurement -This function calculates the heat quantity received and sent with liquid (water) in cooling and heating. Two 4-20mA inputs are available for temperature measurements |
![]() |
|
![]() |
Flow velocity profile measurement(option) -Flow profile can be monitored in real time. Pulse doppler method with specific sensors model FSD is used |
Applicable Fluid |
Homogeneous liquid through which ultrasound can pass, such as |
Applicable pipe inner diameter |
∅13mm to ∅6000mm (depending on detector) |
Measured fluid temperature |
-40 to +200°C (depending on the detector) |
Measurement flow rate range |
0 to ±32 m/s (minimum ±0.3 m/s) |
Measurement accuracy |
±1.0% of rate (depending on aperture and flow rate) |
Calculation/output cycle |
1 second |
Survey line |
Propagation time difference method (one line) |
display |
Backlit color graphic display (TFT LCD monitor) 240*320 pixels |
Analog Output Signal |
DC4 to 20mA (1 point) |
Analog Input Signal |
DC4-20mA (2 points) or DC4-20mA + DC1-5V (1 point) |
Power-supply voltage |
Built-in battery (12 hours continuous operation when fully charged) |
Converter Structure |
Dustproof and waterproof IP64 (without printer) |
Converter size |
210×120×65mm (without printer) |
Mass of transducer |
Approx. 1 kg |
SD Card |
512MB can store data for about 2 years. Maximum 8GB |
Serial communication |
Data transmission (instantaneous values, total values, etc., stored on SD card) |
function |
Damping time constant (0 to 100 seconds) |
option |
Printer included: Screen hard copy, periodic print, logger data print |