Portable durometer combined UCI (ultrasonic) and Leeb (ball rebound) methods. Meets ASTM A1038 and ASTM A596.Control of ferrous and non-ferrous metals. Control of cast iron and various alloys.Determines the tensile strength of pearlitic carbon steels3 modes of use: signal (Leeb); statistics ; smart mode (filter of incorrect measurements)
Type of probe |
D |
DC |
DL |
D+15 |
C |
G |
|
1. Application |
For the majority of your hardness testing requirements. |
Use in very confined spaces, e.g. in holes, cylinders or for internal measure‐ ments on assembled machines. |
For measurements in extremely confined spaces or at the base of grooves. |
For measurements in grooves or recessed surface. |
Surface hardened components, coatings, thin walled or impact sensitive components (small measuring indentation). |
Solid components. E.g. heavy castings and forgings. |
|
2. Impact energy |
11Nmm |
11Nmm |
11Nmm |
11Nmm |
3Nmm |
90Nmm |
|
3. Mass of impact body |
5.5g |
5.5g |
7.3g |
7.8g |
3g |
20g |
|
4. Tip |
· Diameter |
3mm |
3mm |
3mm |
2.78mm |
3mm |
5mm |
· Hardness |
1600HV |
1600HV |
1600HV |
1600HV |
1600HV |
1600HV |
|
· Material |
Tungsten carbide |
Tungsten carbide |
Tungsten carbide |
Tungsten carbide |
Tungsten carbide |
Tungsten carbide |
|
5. Impact device |
· Length |
147mm |
86mm |
202mm |
162mm |
141mm |
254mm |
· Diameter |
20mm |
20mm |
20mm |
20mm |
20mm |
30mm |
|
· Weight |
75g |
50g |
100g |
80g |
75g |
250g |
|
6. Max. hardness of sample |
940HV |
940HV |
950HV |
940HV |
1000HV |
650HB |
|
7. The average roughness of sample |
Ra: 1.6μm |
Ra: 1.6μm |
Ra: 1.6μm |
Ra: 1.6μm |
Ra: 0.4μm |
Ra: 6.3μm |
|
8. Min. weight of sample |
of compact shape |
5 kg / 11lbs |
5 kg / 11lbs |
5 kg / 11lbs |
5 kg / 11lbs |
1.5 kg / 3.3 lbs |
15 kg / 33 lbs |
on solid support |
2 kg / 4.5 lbs |
2 kg / 4.5 lbs |
2 kg / 4.5 lbs |
2 kg / 4.5 lbs |
0.5 kg / 1.1 lbs |
5 kg / 11 lbs |
|
coupled on plate |
0.05 kg / 0.2 lbs |
0.05 kg / 0.2 lbs |
0.05 kg / 0.2 lbs |
0.05 kg / 0.2 lbs |
0.02 kg / 0.045 lbs |
0.5 kg / 1.1 lbs |
|
9. Min. thickness of sample |
uncoupled |
25 mm / 0.98 inch |
25 mm / 0.98 inch |
25 mm / 0.98 inch |
25 mm / 0.98 inch |
15 mm / 0.59 inch |
70 mm / 2.73 inch |
coupled |
3 mm / 0.12 inch |
3 mm / 0.12 inch |
3 mm / 0.12 inch |
3 mm / 0.12 inch |
1 mm / 0.04 inch |
10 mm / 0.4 inch |
|
surface layer thickness |
0.8 mm / 0.03 inch |
0.8 mm / 0.03 inch |
0.8 mm / 0.03 inch |
0.8 mm / 0.03 inch |
0.2 mm / 0.008 inch |
||
10. Indentation size on test surface with 300 HV, 30 HRC |
diameter |
0.54 mm / 0.21 inch | 0.54 mm / 0.21 inch | 0.54 mm / 0.21 inch | 0.54 mm / 0.21 inch | 0.38 mm /0.015 inch | 1.03 mm / 0.04 inch |
depth |
24 μm / 960 μinch |
24 μm / 960 μinch |
24 μm / 960 μinch |
24 μm / 960 μinch |
12 μm / 480 μinch |
53 μm / 2120 μinch |
|
11. Indentation size on test surface with 600 HV, 55 HRC |
· diameter |
0.45 mm /0.017 inch |
0.45 mm /0.017 inch |
0.45 mm /0.017 inch |
0.45 mm /0.017 inch |
0.32 mm / 0.012 inch |
0.9 mm / 0.035 inch |
· depth |
17 μm / 680 μinch |
17 μm / 680 μinch |
17 μm / 680 μinch |
17 μm / 680 μinch |
8 μm / 2560 μinch |
41 μm / 1640 μinch |
|
12. Indentation size on test surface with 800 HV, 63 HRC |
· diameter |
0.35 mm / 0.013 inch |
0.35 mm / 0.013 inch |
0.35 mm / 0.013 inch |
0.35 mm / 0.013 inch |
0.30 mm / 0.011 inch |
|
· depth |
10 μm / 400 μinch |
10 μm / 400 μinch |
10 μm / 400 μinch |
10 μm / 400 μinch |
7 μm / 280 μinch |
UCI probe types |
o 1kgf (10N) 2.2 lbf o 5kgf (50N) 11lbf o 10kgf (98N) 22lbf |
Leeb probe types |
o D o DC o DL o C o D+15 o E o G |
Indenter |
o Diamond indenter (UCI) o Hardened ball (Leeb) |
Hardness scale |
o UCI probe: HRC, HB, HV, MPa o Leeb probe: HRC, HB, HV, HLD, MPa |
Measurement hardness range: o Rockwell, HRC o Brinell, HB o Vickers, HV o Tensile strength, MPa o User calibrations |
o Factory calibrations: – HRC: 20~70 – HB: 90~650 – HV: 100~750 – Tensile strength MPa: 370~1740 o User calibrations for any scale and range (for example: 1-2000HV) |
Measuring accuracy |
o HRC: 2HRC o HB: 10HB o HV: 15HV o HLD: 4HLD |
Standards |
o ASTM A1038 o ASTM A956 o ASTM A370 o ISO 16859 o ASTM E140 o ISO 18265 o DIN 50159 o GB/T 34205 |
Measuring direction |
Any direction 360° |
Materials |
o UCI probe – pre-calibrated for steel. o Leeb probe – pre-calibrated for steel, alloy steel, stainless steel, cast iron. o Additional custom scales and materials for calibration. |
PC cable connection |
o Online – novotest.info o Offline – NOVOTEST AWP |
Wireless connection with Android gadgets via NOVOTEST Lab App |
o T-UD2 – No o T-UD2 (Lab) – Yes |
Storage capacity of measurement results |
o T-UD2 – 256 o T-UD2 (Lab) – 256 in the device + in NOVOTEST Lab App limited only by the memory of the Android gadgets |
Language |
o English o Spanish o Portuguese o French o Russian |
Operating temperature range, ° C |
-20 … +40 |
Power supply |
2pcs AA batteries |
Dimensions, mm |
120x60x25 |
Weight of electronic unit with battery, no more, kg |
0.2 |
Batteries life, not less, h |
20 |
Package gross weight, kg |
2 |
|
![]() |