Two sensors measure vibration during reflow heating. Displays each X, Y, and Z along with the profile in an easy-to-understand manner during gravitational acceleration measurement.
Data Example
Measurement example during reflow heating
Item |
Specification |
Max. measuring time |
Approx. 3 hours (Ni-MH battery)*1*2 |
Sampling time (sec.) |
0.05 , 0.1 , 0.2 , 0.5 , 1.0 , 2.0 , 4.0 , 8.0 Arbitrarily set up possible (synchronized to RCM-S) |
Measuring range / Resolution /Accuracy |
±2.0g (1.0g=9.806 65m/s2) / 0.001g (1.0g=9.806 65m/s2) / ±0.005g (1.0g=9.806 65m/s2) |
Power supply |
Supplied from RCM-S main unit, AAA batteries x 3pcs. |
Outer dimensions |
Main unit: 221 (D) x 50 (W) x 18 (H) mm (with RCM-S main unit, Sensors are not included) Sensor: 45 (D) x 35 (W) x 19 (H) mm Heat resistant case: 360 (D) x 65 (W) x 25 (H) mm |
Weight |
Approx. 800g including RCM-S main unit & batteries, Conveyor attachment system is not included. |