This is a multi-point LP gas detection alarm that can connect up to 12 gas detection units in one unit, which is based on our experience with earthquakes and designed with disaster situations in mind. Designed for disaster situations.This is a multi-point LP gas detection alarm that can connect up to 12 gas detection units to one unit. Earthquake-resistant design takes disasters and major earthquakes into consideration, and units are available in 2, 4, 6, 8, 10, and 12 point types. (2-point monitoring method per unit)

  • Comes with a safety power supply that performs continuous monitoring for 30 minutes after a power outage and intermittent monitoring for 2 days thereafter (optional)
    • Audio notification of gas leak location and abnormality details
    • Easy-to-understand display of gas concentration at the time of alarm occurrence with digital bar graph
    • You can check the battery life with one touch.
    • One-touch zero adjustment and span adjustment
    • Wide operating voltage range is 85 to 264V, and can be applied directly to 200V power supplies.
    • Zero suppression function allows cancellation of slight fluctuations in indicated values due to environmental changes.
    • Multi-point LP gas detection alarm that can connect up to 12 gas detection units to one unit. Designed for disaster situations.
    • Units are available in 2, 4, 6, 8, 10, and 12-point types (2-point monitoring method per unit).
    • Comes with a safety power supply (optional) that performs continuous monitoring for 30 minutes after a power outage and intermittent monitoring for 2 days thereafter.
    • Audio notification of gas leak location and abnormality details.
    • Earthquake-resistant design considering major earthquake disasters.
    • Easy-to-understand digital bar graph display of gas concentration at the time of alarm occurrence.
    • You can check the battery life with one touch.
    • One-touch zero adjustment and span adjustment.
    • The operating voltage range is wide from 85 to 264V, and it can be used as a 200V power supply.
    • Zero suppression function allows cancellation of slight fluctuations in indicated values due to environmental changes.

 

Model

NV-500

Detection principle

Catalytic combustion type

Gas to be detected

LPG

Number of detection points/unit

1 unit 2-point monitoring system

Detection instruction range

0-100% LEL (isobutane)

Gas concentration display meter
alarm setting value display
backlight
peak hold function during alarm

LCD bar graph meter (2 rows of 53 dots) with
alarm setting, direct reading
scale, backlight,
peak value hold during alarm, released by reset

Alarm set value/set value change

24%LEL or 16%LEL/△▽key operation method

alarm accuracy

±25% or less of alarm set value (under the same conditions)

Alarm delay

Within 30 seconds at a concentration 1.6 times the alarm set value
(suction type excludes piping delay)


Alarm display


Individual alarm lamp
self-holding system

Flashes red during alarm, lights
up completely after buzzer stops (turns off by resetting after level drops)


alarm
sound

Standard operation

During alarm: Intermittent sound, stops when buzzer stops

audio alert

Alarm: Intermittent tone + voice message


External alarm
output



Individual alarm contact

No-voltage 1a contact (contact capacity AC100V 2A)

Individual voltage output

DC0-6-12V (20mA or less)

Bulk alarm contact

No-voltage 1c contact (contact capacity AC100V 2A)

Central monitoring panel output

DC0-6-12V (20mA or less)

external buzzer contact

No-voltage 1a contact (contact capacity AC100V 2A)

External buzzer voltage output

Voltage intermittent signal (DC12V 10mA or less)

alarm delay

Can be selected with dip switch (fixed at 10 seconds)

Normal power supply

AC85~264V

power
consumption


When using KD-5

Diffusion type (15+3.5n) VA

When using PE-2DC

Suction type (15+7.5n) VA


security power supply


Storage battery used

sealed lead acid battery

Overdischarge prevention function

With overdischarge prevention function

Storage battery life judgment

With storage battery life judgment function

Storage battery voltage display

2-digit numerical display LED

Paint color

Munsell 2.5PB 7.0/1.0

วิธีการสั่งซื้อสินค้า

ขั้นตอนที่ 1
เลือกสินค้าที่คุณต้องการ โดยคลิกปุ่มสั่งซื้อ / หยิบลงตะกร้า
ขั้นตอนที่2
เมื่อเลือกสินค้าครบแล้ว ให้คลิกปุ่มสั่งซื้อสินค้าในตะกร้าสินค้า
ขั้นตอนที่ 3
กรอกรายละเอียดให้ครบถ้วน จากนั้นคลิกปุ่มยืนยันการสั่งซื้อ
ขั้นตอนที่ 4
ชำระค่าสินค้าและบริการ สามารถดู วิธีการชำระเงินได้ที่นี่
ขั้นตอนที่ 5
แจ้งการชำระเงินผ่านทางหน้าเว็บไซต์ แจ้งชำระเงิน
ขั้นตอนที่ 6
เมื่อทางร้านตรวจสอบรายการชำระเงินเรียบร้อยแล้ว จะจัดส่งสินค้าให้คุณทันที

วิธีการชำระเงิน

ร้านค้านี้ยังไม่ได้กำหนดวิธีการชำระเงิน กรุณา ติดต่อกับทางร้าน เกี่ยวกับรายละเอียดในการชำระเงิน
ทางร้านยังไม่ได้ทำการเพิ่มบัญชีรับเงิน กรุณาติดต่อ เจ้าของร้าน

Contact us


ติดต่อสอบถาม #ภาษาไทย

Contact : Thai/English

หมวดหมู่สินค้า

เครื่องมือวัดอุตสาหกรรม l Measuring Instruments [10217]
เครื่องวัดและเกจเช็คค่าความแข็ง(Hardness Tester) [93]
เครื่องวัดและทดสอบไฟฟ้า(Electrical test and Measurement) [113]
เครื่องวัดอุณหภูมิและความชื้น(Temperature&Humidity Meters) [241]
เครื่องวัดสำหรับงานสอบเทียบ(Calibration Instruments) [14]
เครื่องวัดและชุดทดสอบคุณภาพน้ำ(Water Quality) [170]
เครื่องวัดและบันทึกค่าข้อมูล(Data Logger) [79]
คุณสมบัติการใช้งานเครื่องมือวัด l Featured Products [872]

ระบบสมาชิก

พูดคุย-สอบถาม