รหัสสินค้า | SKU-18317 |
หมวดหมู่ | เครื่องจ่ายไฟกระแสตรง(DC Power Supply) |
ราคาปกติ | |
ลดเหลือ | 0.00 บาท |
สถานะสินค้า | Pre-Order |
ลงสินค้า | 21 ธ.ค. 2566 |
อัพเดทล่าสุด | 22 ต.ค. 2567 |
คงเหลือ | 1 ชิ้น |
จำนวน | ชิ้น |
Specifications/model name |
ZX-S-400LAN |
||
Name/format |
Takasago Manufacturing ZX-S series/Variable CV/CC method DC power supply (equipped with zoom technology) |
||
Output specifications |
Rated output voltage |
80V |
|
Rated output current |
40A |
||
Rated output power |
400W |
||
Output range |
|
||
Output terminal |
Front output terminal |
For output, only the rear output terminal can be attached as a |
|
Rear output terminal shape |
Bar terminal (M5 screw) |
||
Constant voltage characteristics |
Setting range (Setting resolution in parentheses) |
0.00V to 84.00V (setting resolution 10mV) |
|
Setting accuracy (*1) |
±(0.1%+10mV) of setting value |
||
Load regulation (*2) |
±(0.01% of rated output voltage + 3mV) or less |
||
Line regulation (*3) |
±(0.01% of rated output voltage + 2mV) or less |
||
Ripple (effective value) (*4) |
2mV |
||
Noise (PP value) (TYP) (*5) |
50mV |
||
Temperature coefficient (typical value) |
±50ppm/℃ |
||
Transient recovery time (*6) |
1ms |
||
Programming time (*7) |
rising |
70ms±20% (at full load)/70ms±20% (at no load) |
|
falling |
250ms±30% (at full load)/1200ms±30% (at no load) |
||
Maximum sink current |
0.4A±0.1A |
||
Residual voltage when OUTPUT OFF (TYP) |
Within ±10mV |
||
Constant current characteristics |
Setting range (Setting resolution in parentheses) |
0.00A~42.00A (10mA) |
|
Setting accuracy (*8) |
±(0.5%+20mA) of setting value |
||
Load regulation (*9) |
±(0.03% of rated output current + 3mA) or less |
||
Line regulation (*3) |
±(0.03% of rated output current + 2mA) or less |
||
Ripple (effective value) (*4) |
20mA |
||
Temperature coefficient (typical value) |
±100ppm/℃ |
||
Measurement/display |
voltmeter |
display |
4-digit digital meter (maximum display 99.99V) |
Measurement accuracy (*10) |
±(0.1%±2digit(20mV)) of reading |
||
Temperature coefficient (typical value) |
±50ppm/℃ |
||
Ammeter (*16) |
display |
4-digit digital meter (maximum display 99.99A) |
|
Measurement accuracy (*10, *16) |
±(0.5%±4digit(40mA)) of reading |
||
Temperature coefficient (typical value) |
±100ppm/℃ |
||
Power display function available |
4-digit digital meter (displays in conjunction with voltage or current display) |
||
Maximum display: 999.9W |
|||
Power display bar graph |
Approximate output power value displayed with 6-point LED |
||
protection device |
OVP |
Setting range |
1.0V~88.0V |
Setting accuracy |
±(0.2%±5digit(0.5V)) of setting value *10 |
||
motion |
Output OFF, switching stop, input switch cutoff (selectable only for ZX-S-1600) |
||
OCP |
Setting range |
0.5A~44.0A |
|
Setting accuracy |
±(0.6%±5digit(0.5A)) of setting value *10 |
||
motion |
Output OFF, switching stop, input switch cutoff (selectable only for ZX-S-1600) |
||
Overpower protection circuit |
When the output power exceeds the rated power and the internal power loss exceeds the specified value, the output voltage and output current are limited. Automatically resets when it returns to within the rating. |
||
Overtemperature protection circuit |
- If the temperature of the heat dissipation section exceeds 85℃ (ZX-S-1600L/LA: 95℃) due to the fan motor stopping, etc., switching will stop, the output will turn OFF, and an alarm will be displayed. |
||
Excessive input current protection |
fuse 10A |
||
Input specifications |
Operating power supply |
AC85V~250V single phase 45Hz~65Hz |
|
Input terminal shape |
inlet connector |
||
Input current (*11) |
AC100V input |
6A |
|
AC200V input |
3A |
||
Input power factor (*12) |
0.99 or more |
||
Power efficiency (*13) |
75% |
||
Inrush current (peak value) |
AC100V input |
10A |
|
AC200V input |
20A |
||
AC264V input |
25A |
||
remote sensing |
・Can compensate for voltage drop due to the conductor leading to the load up to 1V one way. |
||
Communication function |
LAN communication (standard equipment only for model numbers with N) |
LAN port is standard equipment on model numbers with N * Click here |
|
Serial communication |
- RS-232C (model number without N) and RS-485 allow setting and measurement of output voltage, current, and protection level, as well as reading alarms, status, and various setting states. |
||
External |
|
Possible with small signal contacts or photocouplers (*15: ON/OFF cable sold separately) |
|
◯ |
|||
Output voltage/current control using external voltage (0-10V) |
◯ |
||
Output voltage/current control using external resistance (0-10kΩ) |
◯ |
||
Variable internal resistance {IV characteristic approximation function} |
◯ |
||
Output voltage/current analog monitor output (0-10V) |
◯ |
||
Status output |
(CV)Constant voltage mode operation |
◯ |
|
(CC) Constant current mode operation |
◯ |
||
Internal power supply voltage normal |
◯ |
||
Alarm output |
Minor abnormalities such as OVP, OCP, etc. |
◯ |
|
Any alarm occurs |
◯ |
||
Emergency stop signal (small signal contact, etc.) An |
◯ |
||
Other features |
Start-up mode selection |
Output rise can be selected to prioritize CV or CC |
|
Slew rate variable function |
function |
CV rising/falling and CC rising/falling slew rates can be varied independently |
|
CV |
0.1V/s~160.0V/s |
||
CC [When operating alone] |
0.01A/s~80.00A/s |
||
Memory function |
Up to 3 combinations of output voltage and current can be written and read. |
||
Sequential ON/OFF function |
Output ON/OFF of multiple ZX-S series units can be controlled at different times. (Delay time setting: 0.00 to 99.99s) (Requires multi connection cable sold separately) |
||
Calibration function |
- Voltage setting, current setting offset/full scale can be calibrated by the user |
||
Parallel/series |
Parallel operation |
Maximum number of parallel units |
・One control possible for up to 10 units of the same model (separately sold parallel operation cable required) |
Automatic recognition of number of parallel units |
・Automatic recognition of the number of parallel units eliminates the need to set parameters related to parallel operation. |
||
Collective setting |
The voltage and current values of each power supply connected in parallel can be set and displayed all at once on the master unit. Current values etc. can be set and measured and displayed based on the sum of parallel states. |
||
All display |
|||
Series operation (*14) |
◯ |
||
Insulation (measure insulation resistance with DC500V megger) |
There is insulation between input and output, input and chassis, and output and chassis. (20MΩ or more) |
||
cooling method |
Forced air cooling using output-sensitive fan motor |
||
Operating environment |
Temperature 0°C to 50°C (output power must be derated at a rate of 2.5% per 1°C above 40°C) |
||
External dimensions W x H x D (mm) |
107 x 130 (147) x 405 (505) |
||
Mass (approx.) |
5kg |
||
rack mount |
4 units can be installed |
||
accessories |
input cable |
Power cord set with plug for AC100V, 2P-3P conversion adapter 1.8m |
|
others |
・Output terminal cover |
||
Specifications/model name |
ZX-S-400LA |