Industrial products are being made smaller and smaller these days. The BS-1210/1310 linear gauge baby sensor is the best solution for measurement of such a small product. With the compact body, many sensors can be installed closely together even in a limited space.
The BS-1210/1310, designed based on our long-selling previous model the BS-102/112 series, measures dimensions, displacements and travels in high durability, stability and high accuracy.
Model name |
BS-1310 |
---|---|
Measurement range | 10 mm |
Resolution | 1 µm |
Accuracy (at +20 ℃) | 3 µm |
Maximum spindle velocity *1 | 0.3 (1.2) m/s |
Measurement force(including dust protection rubber) | 1.47 N or less |
Number of strokes *2 | 30 million times |
Vibration resistance (when the power is off)*4 |
98 m/s2 in each of the three axial directions (150 minutes per each) 20 cycles of 10 Hz to 150 Hz sweeping |
Shock resistance(when the power is off)*4 | 980 m/s2 in each direction for each of three axis Three times for each of X, Y, and Z directions (18 times in all, sine half-wave, pulse duration 6 ms). |
Protection class | IP 66 (excluding connector) |
Stem diameter | Φ 8 mm+0 -0.03 |
Power supply | DC 4.5 to 5.5 V |
Power consumption(DC 5 V) | 50 mA or less |
Output signal(DC 5 V) | Two-phase square wave, phase difference: 90°± 20° Output voltage Hi : +4.5 V or more(no load)Lo : +0.4 V or less |
Operating temperature range | 0 to+50 ℃ |
Storage temperature range | -10 to+65 ℃ |
Outer dimensions | 94.5 x 29 x 13 mm |
Cable length | Approx. 1.9 m |
Weight (including cable) | Approx. 110 g |
Accessory | Instruction manual |
Option
|
· AA-813 Mechanical release *2 |
*1:When used with Ono Sokki’s Gauge Counter. The values within parentheses ( ) is the maximum spindle velocity with the
DG-4320/4340/5100.
*2:IP66 is not guaranteed when a release is used.
*3:IP66 is not guaranteed when a measurement tip is used. (Because a dust protection rubber is removed when a measurement tip is used.)
*4:Vibration/shock resistance values described in above are not guaranteed during measurement operation.