รหัสสินค้า | SKU-15443 |
หมวดหมู่ | เครื่องจ่ายไฟกระแสตรง(DC Power Supply) |
ราคาปกติ | |
ลดเหลือ | 0.00 บาท |
สถานะสินค้า | Pre-Order |
สภาพ | สินค้าใหม่ |
ลงสินค้า | 26 มิ.ย. 2566 |
อัพเดทล่าสุด | 26 มิ.ย. 2566 |
คงเหลือ | 1 ชิ้น |
จำนวน | ชิ้น |
name |
Compact wide range DC power supply PWR-01 series |
|
format |
PWR801MH |
|
Basic function |
Direct current power supply (DC) output from commercial power supply (AC100V, 200V) |
|
output |
||
Rating |
output power |
800.0W |
output voltage |
240.00V |
|
output current |
10.00A |
|
Voltage |
Maximum voltage that can be set |
252V |
Setting accuracy |
± (0.5% of set + 0.1% of rating) |
|
Setting resolution |
1000mV |
|
100mV (FINE/OUTOFF), 10mV (FINE/OUTON), 0.1mV (when using communication interface) |
||
Power fluctuation |
±26mV |
|
load change |
±26mV |
|
transient response |
2 ms or less |
|
ripple noise |
100mVp-p, 20mV (rms/measurement frequency band is 10Hz to 1MHz) |
|
rise time |
100ms or less (full load, no load) |
|
fall time |
150ms or less (full load), 1200ms (no load) |
|
Remote sensing |
5V |
|
temperature coefficient |
100ppm/°C (in the range of ambient temperature 0°C to 50°C) |
|
|
||
current |
Settable maximum current |
10.5A |
Setting accuracy |
± (0.5% of set + 0.1% of rating) |
|
Setting resolution |
40mA |
|
10mA (FINE/OUTOFF/), 1mA (FINE/OUTON), 0.1mA (when using communication interface) |
||
Power fluctuation |
±3mA |
|
load change |
±7.0mA |
|
Ripple noise (rms) |
24mA |
|
rise time |
100ms (full load) |
|
fall time |
100ms (full load) |
|
current temperature coefficient |
100ppm/℃ |
|
Maximum settable internal resistance |
18.000Ω |
|
Display function |
||
voltage display |
Maximum display |
999.9 |
Display accuracy |
±(0.2% of reading +5 digits) |
|
current display |
Maximum display |
99.99 |
Display accuracy |
±(0.5% of reading +8 digits) |
|
power display |
Maximum display |
9999 |
Display accuracy |
Switch the display between the multiplication result of the current value and the voltage value |
|
PWR DSPL key lit (red) |
||
AC input |
||
Nominal input rating |
100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase |
|
Input voltage range |
85Vac to 265Vac |
|
Input frequency range |
47Hz to 63Hz |
|
Current |
100Vac |
11.2A |
200Vac |
5.6A |
|
Inrush current (MAX) |
50 Apeak or less |
|
Power (MAX) |
1120 VA |
|
Power factor (TYP value) |
0.99 (input voltage 100 V) / 0.97 (input voltage 200 V) |
|
Efficiency (MIN) |
75% or more |
|
Power failure holding time (MIN) |
20 ms or more |
|
protective function |
||
Overvoltage protection (OVP) |
Output off, OVP display, ALM lighting |
|
Setting range: 10% to 112% of rated output, setting accuracy: ±(1.5% of rating) |
||
Overcurrent protection (OCP) |
Output off, OCP display, ALM lighting |
|
10% to 112% of rated output |
||
Front output terminal overcurrent protection |
Output off, OCP display, ALM lighting |
|
11A (TYP value) |
||
Constant voltage limit (UVL) |
Output off, OCP display, ALM lighting |
|
Setting range: 0% to 105% of rated output voltage |
||
Overheat protection (OHP) |
Output off, OHP display, ALM lighting |
|
Sensing Incorrect Connection Protection |
Output off, SENS display, ALM lighting |
|
Low AC input protection |
Output off, AC indication, ALM lighting |
|
Shutdown (SD) |
Output off, SD display, ALM lighting |
|
POWER LIMIT |
ALM lighting, set value (fixed): about 105% of rated output power |
|
Communication monitoring (WATCHDOG) |
Output off, WDOG display, ALM lighting |
|
Master-slave parallel operation protection |
Output off, PRL display, ALM lighting |
|
Signal output/input |
||
Monitor signal output |
Voltage monitor |
Selectable monitor voltage range: 0V to 5V or 0V to 10V |
Setting accuracy: 2.5% of fs |
||
Current monitor |
Selectable monitor voltage range: 0V to 5V or 0V to 10V |
|
Setting accuracy: 2.5% of fs |
||
Status signal output |
OUT ON STATUS |
On when output is on |
|
CV STATUS |
ON during CV operation |
CC STATUS |
On during CC operation |
|
ALARM STATUS |
ON when alarm is activated |
|
POWER ON STATUS |
On when POWER is on |
|
trigger signal |
Input (TRG IN) |
Logic selectable: LOW (0V to 1.5V), HGH (3.5V to 5V) / Input impedance: 10kΩ (TYP value) |
Output (TRG OUT) |
Logic selectable: LOW (0V to 0.6V), HGH (4.2V to 5V) / Pulse width: 100μs (TYP value) |
|
Control function (external control) |
||
Output voltage control (VPGM) |
0% to 100% of rated output voltage, selectable control voltage: 0V to 5V, or 0V to 10V |
|
Output current control (IPGM) |
0% to 100% of rated output current, selectable control voltage: 0V to 5V, or 0V to 10V |
|
Output ON/OFF control OUTPUT ON/OFF CONT |
Logic selectable: |
|
Output shutdown control |
LOW (0V to 0.5V) or short circuit output off |
|
Alarm clear control ALM CLR |
Alarm clear on LOW (0V to 0.5V) or short circuit |
|
Other features |
||
Output on/off delay |
Setting range: 0.0 s, 0.5 s to 99.9 s (factory setting: 0.0 s) Setting resolution: 0.1 s |
|
Soft start/soft stop |
Setting range: 0.0 s, 0.5 s to 10.0 s (factory setting: 0.0 s) Setting resolution: 0.1 s |
|
Overcurrent protection (OCP) |
Setting range: 0.0 s to 2.0 s (factory setting: 0.0 s) Setting resolution: 0.1 s |
|
preset memory |
Saves up to three combinations of voltage settings, current settings, OVP settings, OCP settings, and UVL settings |
|
key lock |
Disable operations other than the OUTPUT key |
|
config shortcut |
Register up to three config setting items to the SC1, SC2, and SC3 keys |
|
sequence |
Number of programs: 1 Number of steps: 64 |
|
Synchronous operation |
Synchronize voltage and current settings, synchronize step restart of sequence program |
|
One-control parallel operation |
Up to 3 units including the master unit (same model) |
|
Series operation |
2 units (same model) |
|
Multi-channel |
Connection between master unit and PC |
LAN, USB, RS232C |
Slave machine connection |
LANs |
|
Operation display |
||
OUTPUT ON/OFF |
OUTPUT LED lights (green) when output is on |
|
Output on/off delay |
”DLY” lights when setting, ”DLY” blinks during operation |
|
Soft start/ soft stop |
”SS” lights when setting, ”SS” blinks during operation |
|
CV operation |
CV LED lights (green) |
|
CC operation |
CC LED lit (red) |
|
alarm action |
ALM LED lights up (red) when protection function is activated |
|
preset memory |
One of the PRESET A/B/C LEDs lights up (green) when recalling/saving preset memory |
|
key lock operation |
LOCK LED lights up (green) when keys are locked |
|
remote operation |
REMOTE LED lit (green) during remote control |
|
remote operation |
LAN operation |
LAN LED Lighting/blinking (changes depending on the state) |
bleeder circuit |
”HB” lights when hyper bleeder is set |
|
Variable internal resistance (VIR) |
”VIR” lights when setting |
|
sequence |
”SEQ” lights while sequence is running, ”SEQ” blinks while waiting for trigger |
|
interface |
||
Common specifications |
software protocol |
IEEE Std 488.2-1992 |
command language |
Conforms to SCPI Specification 1999.0 |
|
RS232C |
hardware |
Conforms to EIA232D specifications (excluding connectors) |
RJ-45 connector [male] (conversion cable RD-8P/9P is optional) |
||
Baud rate : 1 200, 2 400, 4800, 9600, 19200, 38400, 57 600, 115200 bps |
||
Data length 8 bits, stop bit 1 bit, no parity bit |
||
no flow control |
||
Program message |
LF when receiving, CR/LF when sending |
|
USB |
hardware |
Conforms to IEEE 802.3 100Base-TX/10Base-T Ethernet LXI Specification 2011 Ver.1.4 |
IPv4, RJ-45 connector (Category 5, uses straight cable) |
||
Program message |
LF or EOM when receiving, LF + EOM when sending |
|
device class |
Compliant with USBTMC-USB488 Device Class Specification |
|
LANs |
hardware |
Conforms to IEEE 802.3 100Base-TX/10Base-T Ethernet LXI Specification 2011 Ver.1.4 |
IPv4, RJ-45 connector (Category 5, uses straight cable) |
||
Communication protocol |
VXI-11, SCPI-RAW, HiSLIP |
|
Program message |
VXI-11, HiSLIP: LF or END when receiving, LF + END when sending SCPI-RAW: LF when receiving, LF when sending |
|
General |
||
Mass (body only) |
about 5.5kg |
|
Dimensions (WxTxD) |
142.5×150×420mm |
|
Environmental condition |
Operating environment |
Operating environment |
operating temperature |
operating temperature |
|
operating humidity |
20 %rh to 85 %rh (non-condensing) |
|
storage temperature |
-10°C to +60°C |
|
storage humidity |
90 %rh or less (no condensation) |
|
Altitude |
Up to 2000m |
|
cooling method |
Forced air cooling by fan |
|
ground polarity |
Can be grounded negatively or positively |
|
isolation voltage |
L/ML/MH type: ±500 Vmax, H type: ±800 Vmax |
|
Withstand voltage |
Primary — Between Chassis |
No abnormality after applying 1500 Vac for 1 minute |
primary to secondary |
L / ML / MH type: 1650 Vac applied for 1 minute, no abnormality |
|
Secondary — inter-chassis |
L / ML / MH type: 2300 Vdc, no abnormality after 1 minute |
|
insulation resistance |
Primary — Between Chassis |
500 Vdc, 100 MΩ or more (70% or less) |
primary to secondary |
L / ML / MH type: 500 Vdc, 100 MΩ or more (70 % or less) |
|
Secondary — inter-chassis |
L / ML / MH type: 500 Vdc, 40 MΩ or more (70 % or less) |
|
accessories |
Instruction manual, short bar for chassis connection, M4 screw for output terminal, OUTPUT terminal cover, |
|
Electromagnetic Compatibility (EMC) |
Conforms to the requirements of the following directives and standards |
|
safety |