In convenient construction sites such as tunnel construction and explosives training, blasting sounds can measure 164dB (3170Pa) to high sound pressure drop frequency sound pressure level (1Hz~8kHz) It can be used indoors and outdoors. Due to the special anti-drip treatment, it can be used just by covering it with a microphone. It is smaller in size than traditional all-weather windshields, easy to use and inexpensive
At convenient construction sites such as tunnel construction and explosives training, blasting sounds, etc. can measure 164dB ( 3170Pa ) to high sound pressure drop sound pressure level ( 1Hz~8kHz ) It can be used indoors and outdoors. Due to the special drip-proof treatment, it can be used just by covering it with a microphone. It is smaller in size than conventional all-weather windshields, easy to use and inexpensive. When used in combination with an extension cable (waterproof type), it is also effective in comfortable measurements, such as when the main unit is indoors and the microphone part is outdoors where the target sound source is located
The linear range is 100dB wide, making it easy to set up the sound level meter. [ Newly developed ]
TYPE 6226H
Adopt high sound pressure electret condenser microphone.
The measurement frequency range is 1Hz to 8kHz
Noise Level (LA)
The noise level can be measured by setting the operating characteristics to " FAST or SLOW " and setting the frequency correction to " A characteristics".
The display shows the instantaneous value of the noise level.
The digital display is updated every "second" and the bar display is updated every " 0.1 second".
The sound pressure level can be measured by setting the operating characteristic to " FAST or SLOW " and setting the frequency correction to " C characteristic or F characteristic ".
The display shows the instantaneous value of the noise level.
The digital display is updated "every second" and the bar display is updated "every 0.1 second".
The operating characteristics are set to "Fast or Slow" and the frequency correction is set to " A Characteristics".
Then select the measurement time.
The measuring time can be selected
1 second, 3 seconds, 5 seconds, 10 seconds, 1 minute, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 8 hours and 24 hours.
Manual measurement is also possible.
If you press the "Pause" button during measurement , you can also delete the latest 3 seconds or 5 seconds of data.
The display shows the progress value of LAeq .
Prepare noise levels and equivalent noise levels.
Press the "Start" key.
The hourly noise level ( L05 , L10 , L50 , L90 , L95 ) and single noise exposure level ( LAe ), noise level ( LA ), equivalent noise level ( LAeq ), maximum value ( Lmax ) and minimum value ( Lmin ) can be measured simultaneously.
Storage function, communication function with computer
Storage function
About 800 pieces of data can be recorded.
Calendar function
Equipped with clock function and calendar function.
Output signal provided
AC signal and DC signal output terminals.
You can connect a DAT recorder or a level recorder.
You can also print the data recorded in the memory by connecting a dedicated printer.
Not only can the data stored in the memory be transferred to the personal computer, but the measured data can also be sent to the personal computer in real time.
Any computer equipped with RS-232C function can perform data communication.
Art.-No. |
TYPE 6226H |
Product Name | High Sound Pressure Low Frequency Sound Level Meter |
Range of Measurement | 60〜164dB |
Measurement Frequency range | 1Hz~8kHz |
Microphone | 1/2 inch electret condenser microphone (for high sound pressure) |
Level Range | 10dB step 6 steps |
Linearity Range | 100dB |
Dynamic Characteristics | FAST、SLOW、IMPULSE |
Frequency Correction Characteristics | A、C、FLAT |
Measurement Items | Instantaneous value L p , equivalent noise level L eq , single noise exposure level L E , maximum value L max , minimum value L min , time rate noise L x (5 optional values) |
Measurement Time | 1s, 3s, 5s, 10s, 1min, 5min, 10min, 15min, 30min, 1h, 8h, 24h Manual (maximum 199h59M59S) |
Sampling Interval | 20.8μs(Leq)、10ms(Lmax、Lmin) |
Lx Sampling Interval | 100ms |
Presenter | Backlit LCD (128 x 64 dots) |
Digital display | Numerical display: 4 digits, display cycle: 1s |
Bar display | Representation period: 0.1s |
Warning Sign | Ove r: Displayed at +3 dB from the upper limit of the overload scale Under : Displayed at -0.6 dB from the lower limit of the under signal scale |
Battery Display | 4 levels of remaining amount display |
Memory Function | Instantaneous value or calculated value is stored in memory (800 data) |
Clock Function | Built-in (year / month / day / hour: minute: second) |
Pause Function | In addition to the normal pause function, last-minute data removal |
Calibration Signal | Electrical calibration by built-in oscillator (1kHz sine wave) |
AC Output | Output voltage: 1Vrms (FS), output resistance: 600Ω, load resistance: 10kΩ or more |
DC Output | Output voltage: 2.5V (FS), 0.25V / 10dB, output resistance: 50Ω, load resistance: 10kΩ or more |
I / O Terminal | Interface: RS232C (asynchronous), data length: 8 bits, stop bit: 1 bit, parity: none, transfer speed: 4800, 9600, 19200bps (direct output to printer and computer control and data output) |
Power Supply | 4 AA batteries or AC adapter Current consumption (DC6V) Approximately 2.1VA when using AC adapter |
Temperature / Humidity | Temperature : -10 to 50 ° C Humidity: 30% to 90% (no condensation) |
Size | 85(W)×284(H)×46D) |
Weight | Approximately 420g including batteries |
|