Lutron Real Time Humidity, Barometric Pressure and Temperature Data LoggerThe MHB-382SD is a Real Time Humidity, Barometric Pressure and Temperature Data Logger with a user selectable logging interval from 5 to 600 seconds. All Data can be stored (Date & Time) on an optional SD memory card, which can be viewed and analyzed using an Excel compatible format.
- Easy to View High Contrast 2.36" X 1.96" display of Humidity, Barometer and Temperature on one LCD screen
- Real Time Data Logger of Humidity, Barometer and Temperature. Year, Month, Date, Hour, Minute & Second stored into SD card.
- 5s, 10s, 30s, 60s, 120s, 300s, 600sec selectable sampling time.
- Excel Compatible ideal for graphic analysis
- 10% to 90% R.H. with 0.1% R.H. resolution
- Selectable C/F units. 32°F to 122°F range with 0.1 Degree Temperature resolution
- Selectable barometric pressure units. hPa, mmHg and inHg
- Power: 6pcs AAA (Included)
- SD Card NOT INCLUDED
- Operating Temperature: 32° F to 122° F (0° to 50° C).NOTE most batteries are not rated for below -4° F or above 125° F.
- Operating Humidity: less than 90% RH non-condensing.
- 0.1 %RH resolution for the humidity reading
- 0.1 degree resolution for the Temp. reading
- Professional barometer, unit : hPa, mmHg, inHg
- SD card capacity : 1 GB to 16 GB
- DC 1.5V ( UM-4, AAA ) battery x 6 PCs or DC 9V adapter in
- RS232/USB computer interface
- Weight 240 g/0.53 LB
- Dimension 132 x 80 x 32 mm ( 5.2 x 3.1 x 1.3 inch )
- Optional accessories: AC to DC 9V adapter; USB cable, USB-01; RS232 cable, UPCB-02; Data Acquisition software, SW-U801-WIN
Model number
|
MHB-382SD
|
display
|
LCD size 60×50mm
|
Measurement target
|
temperature, humidity, atmospheric pressure
|
atmospheric temperature
|
range
|
0~50℃
|
resolution
|
0.1℃
|
accuracy
|
±0.8℃
|
humidity
|
range
|
10~90%RH
|
resolution
|
0.1%RH
|
accuracy
|
≧70%RH: ±(4% reading + 1%RH) <70%RH: ±4%RH
|
Atmospheric pressure
|
range
|
10.0~1100hPa
|
resolution
|
0.1hPa
|
accuracy
|
±3hPa (at normal pressure only: 950hpa to 1050hpa)
|
SD card
|
Can be used from 1G to 16G
|
sampling period
|
5,10,30,60,120,300,600 seconds *Initial setting time is set to 60 seconds Automatic
|
Display interval
|
Approximately 1 second
|
Operating temperature measurement environment
|
0 to 50℃ *Please use in an environment with humidity less than 90% and no condensation.
|
power supply
|
6 AAA batteries (*Rechargeable batteries cannot be used) Or AC adapter sold separately
|
Dimensions/weight
|
Body: 132 x 80 x 32mm Approx. 190g (excluding batteries)
|
accessories
|
Main unit, wall mount unit,
|
option
|
SD card reader, AC adapter L, data collection software set SW-808ST (with USB cable LOG-USB2)
|
  |