รหัสสินค้า | SKU-13299 |
หมวดหมู่ | เครื่องวัดคุณภาพน้ำแบบพกพา(Pocket Water Quality Meters),Horiba |
ราคาปกติ | |
ลดเหลือ | 0.00 บาท |
สถานะสินค้า | Pre-Order |
ลงสินค้า | 13 ก.ค. 2565 |
อัพเดทล่าสุด | 23 พ.ย. 2567 |
คงเหลือ | 1 ชิ้น |
จำนวน | ชิ้น |
|
TyU-51 |
U-52 |
U-52G |
U-53 |
U-53G |
|
Simultaneous display of up to 10 items |
Simultaneous display of up to 11 items |
|||||
Sensor |
Measurement temperature |
-10 ~ 55 ° C |
||||
Maximum outer diameter of the sensor |
About 96mm |
|||||
Sensor length |
About 340mm |
|||||
mass |
About 1800g |
|||||
Automatic calibration function |
Use pH4 |
|||||
Turbidity wiper |
— — |
— — |
— — |
● |
● |
|
Measurement depth |
Up to 30m |
|||||
Wet contact material |
PPS, glass, SUS316L, SUS304, FKM, PEEK, Q, titanium, FEP film, POM |
|||||
Waterproof standard |
JIS protection class 8 |
|||||
display |
Display external dimensions |
115 (W) x 66 (D) x 283 (H) mm |
||||
mass |
About 800g |
|||||
LCD |
Graphic LCD with 320 x 240 dot |
|||||
Number of data memory |
10,000 |
|||||
communication |
USB peripheral |
|||||
battery |
4 C-size dry batteries |
|||||
Waterproof standard |
JIS protection class 7 (when sensor cable is connected) |
|||||
Battery life |
70 hours (no backlight) |
500 measurements (without backlight) |
||||
Storage temperature |
-10 to 60 ° C |
|||||
Ambient temperature |
-10 to 45 ° C |
|||||
accessories |
pH4 standard solution (500mL), pH comparison internal solution (250mL), DO sensor internal solution set, DO diaphragm mounting jig, DO sensor spanner, cleaning brush, calibration cup, bag, strap, battery, silicone grease, instruction manual |
|||||
pH ● 2 |
Measurement principle |
Glass electrode method |
||||
range |
pH0-14 |
|||||
resolution |
0.01 pH |
|||||
Reproducibility |
± 0.05 pH |
|||||
accuracy |
± 0.1 pH |
|||||
Redox potential |
Measurement principle |
Platinum electrode method |
||||
range |
-2000mV ~ + 2000mV |
|||||
resolution |
1mV |
|||||
Reproducibility |
± 5 mV |
|||||
accuracy |
± 15mV |
|||||
Dissolved oxygen (DO) |
Measurement principle |
Polarograph method |
||||
range |
0-50.0mg / L |
|||||
resolution |
0.01mg / L |
|||||
Reproducibility |
± 0.1mg / L |
|||||
accuracy |
0 to 20 mg / L: ± 0.2 mg / L |
|||||
Electrical conductivity |
Measurement principle |
AC 4-pole method |
||||
range |
0-10S / m (0-100mS / cm) |
|||||
resolution |
0.1% FS |
|||||
Reproducibility |
± 0.5% FS |
|||||
accuracy |
± 1% FS (midpoint of 2-point calibration) |
|||||
salt |
Measurement principle |
Electrical conductivity (conductivity) conversion |
||||
range |
0-70 PPT (per mille) |
|||||
resolution |
0.1PPT |
|||||
Reproducibility |
± 1 PPT |
|||||
accuracy |
± 3PPT |
|||||
Total amount of dissolved |
Measurement principle |
Electrical conductivity (conductivity) conversion |
||||
range |
0-100g / L |
|||||
resolution |
0.1% FS |
|||||
Reproducibility |
± 2g / L |
|||||
accuracy |
± 5g / L |
|||||
Seawater specific density |
Measurement principle |
Electrical conductivity (conductivity) conversion |
||||
range |
0-50σt |
|||||
resolution |
0.1σt |
|||||
Reproducibility |
± 2σt |
|||||
accuracy |
± 5σt |
|||||
temperature |
Measurement principle |
Platinum thermometer |
||||
range |
-10 to 55 ° C |
|||||
resolution |
0.01 ° C |
|||||
Reproducibility |
± 0.10 ° C (at the calibration point) |
|||||
Element class |
Platinum temperature gauge JIS class B |
|||||
Turbidity (TURB) |
Measurement principle |
— — |
LED front 30 ° transmission scattering method |
Tungsten lamp 90 ° transmission scattering method |
||
range |
0-800 NTU |
0-1000 NTU |
||||
resolution |
0.1NTU |
0.01NTU |
||||
Reproducibility |
± 5% (Reading) or |
± 3% (Reading) or |
||||
accuracy |
± 5% (Reading) or ± 1 NTU |
0 to 10 NTU: ± 0.5 NTU |
||||
Water depth |
Measurement principle |
— — |
— — |
Pressure method |
||
range |
0-30m |
|||||
resolution |
0.05m |
|||||
Reproducibility |
± 1% FS |
|||||
accuracy |
± 0.3m |
|||||
GPS |
Reception method |
— — |
— — |
12 channel parallel |
— — |
12 channel parallel |
Measurement accuracy |
30m or less (2drms) |
30m or less (2drms) |