| รหัสสินค้า | SKU-13280 |
| หมวดหมู่ | เครื่องวัดคุณภาพน้ำแบบพกพา(Pocket Water Quality Meters),Horiba |
| ราคาปกติ | |
| ลดเหลือ | 0.00 บาท |
| สถานะสินค้า | Pre-Order |
| ลงสินค้า | 10 ก.ค. 2565 |
| อัพเดทล่าสุด | 28 ก.ค. 2568 |
| คงเหลือ | 1 ชิ้น |
| จำนวน | ชิ้น |

"It takes time to prepare. I want to use it immediately on site ..."[All-in-one case]

set content:

| Model | D-210PC-S | D-220PC-S |
|---|---|---|
| Measurement item | pH / ORP / electrical conductivity / TDS / resistivity / salinity / temperature | |
| range of measurement |
pH 0.00 ~ 14.00 |
|
| accessories |
Carrying case |
Carrying case |
| Data memory | 500 | 1000 |
| PC / printer connection | ―――― | Possible |
| Size / weight | W80 x D40 x H160 240g (meter body without batteries) | |
|
pH |
|
|
Measurement method |
Glass electrode method |
|
range of measurement |
pH 0.00-14.00 |
|
Display range |
-2.00-16.00 |
|
Display resolution |
0.01 pH |
|
Accuracy (instrument reproducibility) |
± 0.01 pH ± 1 digit |
|
Calibration score |
5 points (for NIST, USA) |
|
pH standard solution |
NIST, USA, DIN |
|
ORP |
|
|
range of measurement |
± 2000mV |
|
Display resolution |
+ 2000mV to -2000mV: 1mV |
|
Instrument reproducibility |
+ 2000 mV to -2000 mV: ± 0.3% |
|
Calibration function |
● |
|
temperature |
|
|
Measurement method |
Thermistor method |
|
Measurement / display range |
-30.0 ~ 130.0 ℃ |
|
Display resolution |
0.1 ℃ |
|
Accuracy (instrument reproducibility) |
± 0.5 ℃ |
|
Calibration function |
● |
|
Conductivity |
|
|
Measuring method |
AC bipolar method |
|
range of measurement |
0.00μS / cm-200.0mS / cm |
|
resolution |
4 significant digits (automatic range change) |
|
Accuracy (instrument reproducibility) |
± 0.6% of the full scale of each range |
|
Reference temperature |
15-30 ℃ |
|
Temperature coefficient |
0.00-10.00% |
|
Cell constant |
0.1, 1.0, 10.0 / cm |
|
Calibration score |
Up to 4 points (automatic) / up to 5 points (manual) |
|
Unit switching |
S / cm, S / m |
|
Total Amount of Substance (TDS) |
|
|
Measurement method |
Conductivity conversion |
|
range of measurement |
0.00ppm-100ppt (TDS coefficient = 0.5) |
|
resolution |
0.01ppm (mg / L) /0.1ppt (g / L) |
|
Accuracy (instrument reproducibility) |
± 0.6% of reading |
|
TDS mode |
Linear (0.40-1.00), EN27888, 442, NaCl |
|
Resistivity |
|
|
range of measurement |
0.001MΩ ・ cm ~ 20.0MΩ ・ cm |
|
resolution |
4 significant digits |
|
Accuracy (instrument reproducibility) |
Full range: ± 0.6% of full scale |
|
Salinity |
|
|
Measurement method |
Conductivity conversion |
|
range of measurement |
0.0-100.0ppt / 0.00-10.00% |
|
resolution |
0.1ppt / 0.01% |
|
Accuracy (instrument reproducibility) |
± 0.6% of reading |
|
Salinity conversion mode |
NaCl, seawater |
|
Calibration function |
● |
|
Data memory |
500 |
|
Data logging (interval memory) |
● |
|
Stable judgment function |
Auto hold, auto stable, instantaneous value |
|
Sensitivity / asymmetric potential display |
● |
|
Calibration interval alarm function |
● |
|
Auto power off function (OFF, 1-30 minutes) |
● |
|
Electrode status display |
● |
|
Battery level display |
● |
|
Error message display |
● |
|
PC connection 1 |
- |
|
Printer connection 2 |
- |
|
display |
Backlit monochrome custom LCD |
|
Waterproof / dustproof grade |
IP67 equivalent |
|
power supply |
2 AA alkaline batteries (Ni-MH rechargeable batteries can be used) |
|
Battery power consumption (standby) |
Battery voltage 3V 5mA or less |
|
External dimensions |
160 (vertical) x 80 (width) x 40.60 (height) mm |
|
mass |
Approximately 220g (without batteries) |
|
Ambient operating temperature / humidity |
0-45 ° C Relative humidity 0-80% (however, no condensation) |











Realtools Asia(ศูนย์รวมเครื่องมือวัดและชุดทดสอบอุตสาหกรรม)