รหัสสินค้า | SKU-13280 |
หมวดหมู่ | เครื่องวัดคุณภาพน้ำแบบพกพา(Pocket Water Quality Meters),Horiba |
ราคาปกติ | |
ลดเหลือ | 0.00 บาท |
สถานะสินค้า | Pre-Order |
ลงสินค้า | 10 ก.ค. 2565 |
อัพเดทล่าสุด | 28 ก.ค. 2568 |
คงเหลือ | 1 ชิ้น |
จำนวน | ชิ้น |
"It takes time to prepare. I want to use it immediately on site ..."[All-in-one case]
set content:
Model | D-210PC-S | D-220PC-S |
---|---|---|
Measurement item | pH / ORP / electrical conductivity / TDS / resistivity / salinity / temperature | |
range of measurement |
pH 0.00 ~ 14.00 |
|
accessories |
Carrying case |
Carrying case |
Data memory | 500 | 1000 |
PC / printer connection | ―――― | Possible |
Size / weight | W80 x D40 x H160 240g (meter body without batteries) |
pH |
|
Measurement method |
Glass electrode method |
range of measurement |
pH 0.00-14.00 |
Display range |
-2.00-16.00 |
Display resolution |
0.01 pH |
Accuracy (instrument reproducibility) |
± 0.01 pH ± 1 digit |
Calibration score |
5 points (for NIST, USA) |
pH standard solution |
NIST, USA, DIN |
ORP |
|
range of measurement |
± 2000mV |
Display resolution |
+ 2000mV to -2000mV: 1mV |
Instrument reproducibility |
+ 2000 mV to -2000 mV: ± 0.3% |
Calibration function |
● |
temperature |
|
Measurement method |
Thermistor method |
Measurement / display range |
-30.0 ~ 130.0 ℃ |
Display resolution |
0.1 ℃ |
Accuracy (instrument reproducibility) |
± 0.5 ℃ |
Calibration function |
● |
Conductivity |
|
Measuring method |
AC bipolar method |
range of measurement |
0.00μS / cm-200.0mS / cm |
resolution |
4 significant digits (automatic range change) |
Accuracy (instrument reproducibility) |
± 0.6% of the full scale of each range |
Reference temperature |
15-30 ℃ |
Temperature coefficient |
0.00-10.00% |
Cell constant |
0.1, 1.0, 10.0 / cm |
Calibration score |
Up to 4 points (automatic) / up to 5 points (manual) |
Unit switching |
S / cm, S / m |
Total Amount of Substance (TDS) |
|
Measurement method |
Conductivity conversion |
range of measurement |
0.00ppm-100ppt (TDS coefficient = 0.5) |
resolution |
0.01ppm (mg / L) /0.1ppt (g / L) |
Accuracy (instrument reproducibility) |
± 0.6% of reading |
TDS mode |
Linear (0.40-1.00), EN27888, 442, NaCl |
Resistivity |
|
range of measurement |
0.001MΩ ・ cm ~ 20.0MΩ ・ cm |
resolution |
4 significant digits |
Accuracy (instrument reproducibility) |
Full range: ± 0.6% of full scale |
Salinity |
|
Measurement method |
Conductivity conversion |
range of measurement |
0.0-100.0ppt / 0.00-10.00% |
resolution |
0.1ppt / 0.01% |
Accuracy (instrument reproducibility) |
± 0.6% of reading |
Salinity conversion mode |
NaCl, seawater |
Calibration function |
● |
Data memory |
500 |
Data logging (interval memory) |
● |
Stable judgment function |
Auto hold, auto stable, instantaneous value |
Sensitivity / asymmetric potential display |
● |
Calibration interval alarm function |
● |
Auto power off function (OFF, 1-30 minutes) |
● |
Electrode status display |
● |
Battery level display |
● |
Error message display |
● |
PC connection 1 |
- |
Printer connection 2 |
- |
display |
Backlit monochrome custom LCD |
Waterproof / dustproof grade |
IP67 equivalent |
power supply |
2 AA alkaline batteries (Ni-MH rechargeable batteries can be used) |
Battery power consumption (standby) |
Battery voltage 3V 5mA or less |
External dimensions |
160 (vertical) x 80 (width) x 40.60 (height) mm |
mass |
Approximately 220g (without batteries) |
Ambient operating temperature / humidity |
0-45 ° C Relative humidity 0-80% (however, no condensation) |