A popular model for temperature and humidity management and control. Dustproof and waterproof IP65 standard
Temperature: -20 to + 80 ° C Humidity: 0 to 100% RH Output: 4 to 20 mA Supply voltage: 12 to 40 VDC
Factory, agriculture, clean room or pharmaceutical plant, hospital, warehouse, computer room. Temperature and humidity converter for air conditioning (HVAC) system. Fast response speed because of popularity.
product name |
---|
Temperature and humidity converter transmitter TRHMJ-303W wall mounting type |
Temperature and humidity converter transmitter TRHMJ-303D duct mounting type |
A popular model for temperature and humidity management and control. Dust and waterproof IP65 standard
Temperature: -20 to + 80 ° C Humidity: 0 to 100% RH Output: 4 to 20 mA Supply voltage: 12 to 40 VDC
Platinum sensor is used. Uses a long-term stable thin film polymer capacitor that accurately senses humidity. It has a structure that facilitates natural convection with a natural ventilation type ventilation tube.
It is easy to install on a pole set up outdoors.
product name |
---|
Temperature gauge with shield TRH-3203 |
Temperature and humidity converter transmitter TRHMJ-303D |
Unique ∅ 6 mm slender probe Length: 150 mm SUS 316 stainless steel
Measurement range: (Temperature) 0 to + 100 ° C / (Humidity) 0 to 100% RH, Accuracy: (Temperature) ± 0.5 ° C / (Humidity) ± 3% RH
Sensor: (temperature) RTD PT 100 Ω / (humidity) thin film capacitor, output: 4-20 mA
product name |
---|
Temperature and humidity converter MJ-TH331 |
Outdoor / indoor illuminance measurement can be easily installed. IP65 waterproof structure
illuminance: 0-2000lx 0-20,000lx 0-200,000lx 4-20mA
output. Stainless steel probe.
product name |
---|
Illuminance converter LXT-401A |
CO2 measurement range: 0 to 50,000 ppm NDIR system adopted. Stationary monitor.
Configuration of display unit and sensor unit. Large liquid crystal display
Automatic control of ventilation fan etc. by external contact (relay output) is possible. Alarm alert.
Used in chemical plant, food / beverage plant, winery / beer plant, oil / gas plant, waste treatment plant, wastewater treatment plant
product name |
---|
CO2 installation type alarm MJ-CO2-5P |
Display unit (child unit) RDU for MJ-CO2-5P |
One unit can measure CO2, temperature and humidity. Voltage, current analog output possible · Relay output (1 channel)
CO2 measurement range: 0 to 2000 ppm (or 0 to 5000 ppm)
Temperature: 0 to 50 ° C Humidity: 3% RH or less (10 to 90% RH)
product name |
---|
CO2 temperature and humidity converter CF135-RB1XXR |
CO2 ・ Temperature and humidity converter CF132-RB1XDR |
CO2 / Temperature and humidity converter CF135-RB1XDR |
CO2 / Temperature and humidity converter CF132-RB1XXR |
2ch voltage data logger Data logger
communication cable and software for measuring and recording voltage signals . Input cable VR-7101x2 included Cable length: 1 m
± 1, 2, 6, 15 V (Auto range) / (Fixed range)
Measurement range: 1 to 5 V , 4 to 20 mA Optional VR + 7103 ( 4 to 20 mA probe)
meter You can record the output signal of the sensor and various sensors. Arbitrary unit display function is provided, and voltage signals can be converted to arbitrary units for display.
Recording capacity: 8000 x 2 Battery life: about 5 to 9 months
product name |
---|
Voltage logger VR-71 (with input cable VR-7101 x 2) |
4-20 mA cable VR-7103 |
Input cable VR-7101 |
Input cable VR-7102 |
4-20mA probe VR-7103
cable length 1m / internal resistance 100Ω
Output: 2V at 2mA / 4mA at 0.4V
■ Output current: 4mA / 12mA / 20mA third gear ■ Small size, easy to hold ■ Operation low voltage warning ■ Range: 4mA, 12mA, 20mA
product name |
---|
Portable current signal generator CC-MA |