Modular type reflow checker RCX-1 (RCM-S) Malcolm's original reflow control equipment series.
Basic unit for 6ch temperature measurement. This is a new concept series that allows you to add the necessary measurement units (☆ 12ch temperature measurement unit ☆ Reflow camera ☆ Oxygen concentration ☆ Wind speed sensor ☆ Vibration sensor ☆ Wireless LAN). Used in various processes such as reflow ovens, flow soldering baths, drying ovens, and heat-resistant loggers.
![]() |
![]() |
Memory unit model |
RCM-S <Modular type reflow checker> |
Measurement temperature range |
0~500℃ *Note 1 |
Maximum measurement time |
10 hours *Note 1 *Note 2 |
Sampling period (seconds)/maximum storage time |
0.05 seconds/4h50min, 0.1 seconds/10h40min, 0.2 seconds/21h20min, 0.5 seconds/48h20min, 1.0 seconds/96h40min, 2.0 seconds/193h20min, 4.0 seconds/386h40min, 8.0 seconds/773h20min Can be set arbitrarily |
temperature accuracy |
±1℃ |
Number of measurement points |
1-6 points |
heat resistant connector |
miniature connector |
thermocouple |
Thermocouple JIS-K 1KΩ or less |
0.1 10m) |
|
power supply |
AAA battery |
Compatible with manganese batteries, alkaline batteries, and nickel metal hydride batteries |
|
External dimensions |
Memory core: width 55mm length 170mm thickness 18mm 200g |
Heat-resistant case: Width 65mm Length 245mm Thickness 25mm 370g |
|
Data transfer method |
USB(miniB), Bluetooth |
weight |
Approximately 570g (including heat-resistant case and battery) |
Model |
RCF-3 |
power supply |
AC100V to 240V (approx. 15W) 50/60Hz |
fan |
Square 120mm (2.9m3/min MAX) 2 pieces |
input gas |
Air 0.5Mpa or less Connection screw Rc 1/8 |
External dimensions |
350(W)×240(D)×160(H) (mm) *When assembled |
weight |
Approximately 5kg |