รหัสสินค้า | SKU-07678 |
หมวดหมู่ | เครื่องทดสอบและอุปกรณ์ตรวจสอบ(Test and Inspection Equipment) |
ราคาปกติ | |
ลดเหลือ | 0.00 บาท |
สถานะสินค้า | Pre-Order |
ลงสินค้า | 13 มิ.ย. 2564 |
อัพเดทล่าสุด | 12 ก.พ. 2566 |
คงเหลือ | 1 ชิ้น |
จำนวน | ชิ้น |
The Rion VM-55 is a 3-Axis vibration meter that can be used in a wide range of applications for measurement and analysis of different parameters.
The unit is equipped to measure the instantaneous value for vibration level and vibration acceleration level, as well as the time percentile level, time averaged level, maximum and minimum values in three axes simultaneously
VX-55EX Extended Function Program The VX-55EX is first necessary in order to install the VX-55WR and VX-55RT. It adds an auto store function, marker function, comparator function and continuous data output function. The VX-55EX program is supplied on a 512 MB SD card. After installation, the card can be used as a 512 MB SD memory card.
VX-55WR (Waveform Recording Program) The VX-55WR enables simultaneous vibration level processing and waveform recording. Recorded data (Non-compressed WAVE files) can be analysed on a computer and can be used for example to perform frequency analysis.
VX-55RT (1/3 Octave Real-time Analysis Program) The VX-55RT enables real time 1/3 octave band analysis. Saved analysis can be reloaded later for display.
AS-60VM (Data Management Software for Environmental Measurement) The AS-60VM manages the data collected with VM-55 from a computer. It allows the use of auto stored data to perform the simultaneous display of time-level and graphs, the simultaneous display of multiple channels, graph overlay, various types of processing operations, and report creation.
AS-60MRT (1/3 Octave Vibration Level Data Management Software) The AS-60VMRT manages data collected with VM-55 from a computer. It allows the use of auto stored 1/3 octave band data to be used for graph display of 1/3 octave band analysis results, various types of processing operations, and report creation.
AS-70 (Waveform Analysis Software) The AS-70 allows the use of WAVE files recorded with the VM-55 to be used for graph display, level processing, frequency analysis (octave band analysis/FFT analysis), file output and playback.
Conformity standard | Measurement method Vibration level meter JIS C 1510: 1995 |
JIS C 1517: 2014 | ||
---|---|---|---|---|
Test based on the new standard that came into effect on November 1, 2015 | ||||
CE Marking (EMC Directive 2004/108 / EC, Low Voltage Directive 2006/95 / EC) WEEE Directive, Chinese RoHS (For China Export Only) |
||||
Measurement function | Simultaneous measurement in 3 directions is possible Vibration level Lv and vibration acceleration level Lva Maximum value hold of vibration level and vibration acceleration level |
|||
Computational measurement (calculated value) |
Time average level of vibration level and vibration acceleration level Leq Time rate level of vibration level and vibration acceleration level L5, L10, L50, L90, L95 Maximum value of vibration level and vibration acceleration level Lmax Minimum value of vibration level and vibration acceleration level Lmin |
|||
Measurement frequency range |
Vibration level | 1-80 Hz | ||
Vibration acceleration level |
1-80 Hz | |||
Measurement level range |
Vertical direction of vibration level |
25-120 dB | 25-129 dB | |
Horizontal vibration level |
30-120 dB | 30-122 dB | ||
Vibration acceleration level |
30-120 dB | 30-129 dB | ||
Self-noise level |
Vertical direction of vibration level |
19 dB or less | ||
Horizontal vibration level |
24 dB or less | |||
Vibration acceleration level |
24 dB or less | |||
Frequency weighting characteristics |
Vertical vibration characteristics (according to the measurement method or JIS), horizontal vibration characteristics (according to JIS), flat characteristics (according to JIS) |
|||
Level range | 10 dB step 6 range switching, 3 directions independent 0 to 70 dB, 10 to 80 dB, 20 to 90 dB, 30 to 100 dB, 40 to 110 dB, 50 to 120 dB |
|||
Linearity range |
80 dB | |||
Efficacy detection circuit |
Digital calculation method, time weighting characteristic 0.63 seconds | |||
Sampling cycle |
Time average level, maximum value, minimum value, maximum value hold 125 μs (sampling frequency 8 kHz) time rate level 100 ms |
|||
Store mode | Manual, Auto * 2, Timer Auto * 2 | |||
Manual | Record the measurement result for each address together with the measurement start time. Record the data in the internal memory of the main unit or the SD card. |
|||
Instantaneous value and maximum value hold value storage |
Saves the instantaneous and maximum hold values of the vibration level Lv and vibration acceleration level Lva when the Pause key is pressed in the current state. |
|||
Save calculated value | Saves various calculated values calculated by Manual | |||
Auto * 2 | Continuous recording of instantaneous values and various calculated values of vibration level Lv and vibration acceleration level Lva Data is recorded on the SD card (not recorded in the internal memory of the main unit) |
|||
Timer Auto * 2 |
Continuous recording of instantaneous values and various calculated values of vibration level Lv and vibration acceleration level Lva Measurement is performed for 10 minutes from every hour by setting the start and stop times. With Sleep function that is in power saving mode until the start of measurement Data is recorded on the SD card (not recorded in the internal memory of the main unit) |
|||
Measurement time | Measurement time in store mode Manual Measurement measurement is possible with the set measurement time 500 seconds, 10 seconds, 1 minute, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 8 hours, 24 hours, user setting ( 1-59 s, 1-59 m, 1-24 h) |
|||
Total measurement time | Store Mode Auto / Timer Auto measurement time at can be set and measured time calculating measurements 500 seconds, 10 seconds, 1 minute, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 8 hours, 24 hours, User settings (1-59 s, 1-59 m, 1-1000 h) |
|||
Lv store cycle | Select from store mode Auto, timer Atuo instant value data store interval 100 ms, 1 s |
|||
Leq calculation cycle | Interval to calculate calculated values such as Leq and LN in store mode Auto and Timer Atuo 10 seconds, 1 minute, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 8 hours, 24 hours, user setting (1) ~ 59 s, 1 ~ 59 m, ~ 24 h) |
|||
Pause function | Pause / pause can be canceled during current state and manual calculation. Pause during Auto / Timer Auto, not possible when recording waveform |
|||
Marker * 2 | Two types of marker functions Valid only when the Lv store cycle is set in store mode Auto and Timer Auto. |
|||
Data recall |
Browse store data | |||
Setting memory | Save and call up to 5 sets of settings in the internal memory of the main unit and SD card It is possible to start with the settings of the file stored in the SD card in advance |
|||
Clock function | It is possible to add time information to store data and perform arithmetic measurement using a timer. |
|||
display | Backlit TFT color translucent liquid crystal display, WQVGA (400 x 240 dots) | |||
Bar graph update cycle: 100 ms, numerical display update cycle: 1 s, language: English and Japanese, Help function: Yes |
||||
Warning display | Excess signal display: Full scale +10.0 dB Under signal display: Full scale -70.5 dB |
|||
led | 2 colors (red / blue), various operating states are displayed | |||
Calibration output signal | Signal output to calibrate externally connected equipment AC output: 31.5 Hz, 1 Vrms, DC output: 2.5 V |
|||
AC / DC output | Select AC output or DC output from the menu Ø2.5 Output terminal, 3 directions independent |
|||
AC output | Output resistance: 600 Ω, load resistance: 10 kΩ or more, AC output: 1 Vrms (full scale) The instantaneous value of the screen and the frequency correction of the AC output can be set independently. |
|||
DC output | Output resistance: 600 Ω Load resistance: 10 kΩ or more DC output: 2.5 V (full scale, 25 mV / dB) |
|||
USB | Mass storage class: Connected to a computer as a storage device and the SD card is recognized as a removable disk Communication device class: Communication device class can be used to control by communication commands |
|||
RS-232C communication | RS-232C communication is possible by using a dedicated cable (using I / O terminal) | |||
BMP file | Screen capture and save in BMP file format | |||
Print function | Print the measurement results on the dedicated printer DPU-414 (using the I / O terminal) | |||
Screen print mode |
Print one display screen. Instantaneous value, calculated value, recall data can be printed out |
|||
Comparator * 2 |
When the vibration level or vibration acceleration level exceeds the set level (30 to 120 dB, in 1 dB increments), the open collector output turns ON. |
|||
Supported channels | One direction set on the Menu screen | |||
Comparator output |
Open collector output (using I / O terminal) Maximum applied voltage: 24 V Maximum drive current: 50 mA (when applied voltage is 24 V) |
|||
SD card | SD / SDHC (maximum capacity 32 GB) * 1 | |||
SD card format |
SD card format is equivalent to SD formatter | |||
Power supply | 8 AA batteries or external power supply | |||
Battery operating time (23 ° C) |
Alkaline battery LR6: Approximately 27 hours Nickel-metal hydride rechargeable battery: Approximately 27 hours (eneloop proⓇ ) |
|||
AC adapter | NC-98C | |||
External power supply voltage | 5 to 7 V (rated voltage 6 V) | |||
Current consumption | Approximately 80 mA (at DC12 V (8 batteries)) Primary side (AC100 V side) Power consumption: Approximately 4 VA (at NC-98C, AC100 V) |
|||
Dustproof and waterproof performance | IP54 * 3 | |||
Operating temperature and humidity range | Temperature: -10 to + 50 ° C, Humidity: 90% RH or less (no condensation) | |||
Size / weight | Approximately 175 mm (H) x 175 mm (W) x 40 mm (D), approximately 780 g (including batteries) | |||
Vibration pickup: 3-way vibration pickup PV-83C |
Reference sensitivity: 60 mV / (m / s2) Operating temperature range: -10 to +50 ° C (no condensation) Waterproof: IPx7 Size / Weight: Approx. Ø67 x 40.7 mm (D) (excluding connection cord), About 335g |
|||
accessories | EC-54S (3 m) x 1, AA alkaline batteries x 8, storage case x 1 |