เครื่องมือวัดอุตสาหกรรม l Measuring Instruments [10259]
คุณสมบัติการใช้งานเครื่องมือวัด l Featured Products [872]
รหัสสินค้า | SKU-06951 |
หมวดหมู่ | เครื่องวัดและตรวจจับก๊าซ(Gas measurement l Gas detector) |
ราคาปกติ | |
ลดเหลือ | 0.00 บาท |
สถานะสินค้า | Pre-Order |
ลงสินค้า | 1 มิ.ย. 2564 |
อัพเดทล่าสุด | 1 มิ.ย. 2564 |
คงเหลือ | 1 ชิ้น |
จำนวน | ชิ้น |
--- | Measurement range | accuracy | resolution |
---|---|---|---|
O2 | 0-21 Vol% | ± 0.2 Vol% | 0.1Vol% |
CO (with H2 compensation) |
~ 0 8,000Ppm |
± 10ppm or ± 1.0% of measured value (0 to 200ppm) ± 20ppm or ± 5% of measured value (201 to 2,000ppm) ± 10% of measured value (2,001 to 8,000ppm) |
1ppm |
CO (without H2 compensation) |
~ 0 4,000Ppm |
± 20ppm ( 0-400ppm) ± 5% of measured value (401-2,000ppm) ± 10% of measured value (2,001-4,000ppm) |
1ppm |
Atmospheric CO (using CO probe for indoor environment measurement) |
0-500ppm | ± 5ppm (0-100ppm) ± 5% of measured value (> 100ppm) |
1ppm |
temperature | -40 to 1200 ° C | ± 0.5 ℃ (0-100.0 ℃) ± 0.5% (> 100 ℃) |
0.1 ℃ (-40 ~ + 999.9 ℃) 1 ℃ (> + 1000 ℃) |
Draft pressure | -9.99 ~ + 40.00hPa | ± 0.02hPa or ± 5% of the measured value (-0.50 to +0.60hPa) 0.03hPa (-0.61 to +3.00hPa) ± 1.5% of the measured value (3.01 to 40.00hPa) |
0.01hPa (0.001hPa when using micro differential pressure probe) |
Differential pressure | 0- + 300hPa | ± 0.5hPa (0 to + 500hPa) ± 1% of the measured value (50.1 to 100.0hPa) ± 1.5% of the measured value (100.1 to 300.0hPa) |
0.1HPa (low differential pressure probe used during 0.01hPa) |
CO2 (calculation from O2) |
0-CO2Max | ± 0.2 Vol% | 0.1Vol% |
Optional COlow (with H2 compensation) |
0-500ppm | ± 2ppm (0-39ppm) ± 5% of measured value (40-500ppm) |
0.1ppm |
Gas leak detection (using gas leak detection probe) |
~ 10,000Ppm 0 CH4 (methane) / C3H8 (propane) |
LED lamp (buzzer sound) |
--- |
Atmospheric CO2 (using CO2 probe for indoor environment measurement) |
0 to 1 Vol.% 0 to 10,000 ppm |
± 50ppm or ± 2% of measured value (0 to 5,000ppm) ± 100ppm or ± 3% of measured value (5,001 to 100,000ppm) |
--- |
display | Color display 240 × 320 Pixel |
mass | About 573g |
---|---|---|---|
External dimensions | 240 x 85 x 65 mm | Operating temperature | -5 to 45 ° C |
Storage temperature | -20 to 50 ° C | memory | 500 data |
Battery type | Lithium ion rechargeable battery |
Warranty period | Measuring instrument body & exhaust gas probe: 1 year Gas measurement sensor: 1 year Thermocouple & rechargeable battery: 6 months (Consumables are not covered by warranty) |
set content | Main unit, exhaust gas probe, AC adapter (with USB cable), attache case |