(1) Connect the transmitter.
The transmitter connection point is the primary side of the string breaker in the relay terminal box.
Turn off the string breaker during exploration.
* If the breaker is ON, the signal may be supplied from the power conditioner and the receiver may not respond.
(2) Exploring with a receiver (4-point exploration)
* Exploring the bus bar.
(1) Search the bus bars at the four corners of the module, and if even one location does not respond, the module is disconnected.
(2) Search for the interconnector of the module, and if the cluster part is unresponsive, it is a disconnection in the cluster.
(3) Trace the interconnector of the module, and if there is an unreacted part, the interconnector in the cell is broken.
Correspondence function for failure mode of solar cell module
* When the failure phenomenon of the solar cell module is a decrease in power generation output
No string output
* The series electric circuit including the module in the string is broken.
(1) Poor continuity of module connection connector or disconnection of module connection wire
(2) Damage to bypass diode in module (open) + disconnection of bus bar or disconnection of interconnector or damage to solar cell
[Corresponding function]
・ Identification of failed solar cell module
・ Between modules Identification of wiring breaks
/ identification of poorly conducted module connection connectors
The string output is low.
* The series electric circuit in the module is broken.
(1) Module bus bar disconnection
(2) Solar cell interconnect connector complete disconnection
(3) Solar cell cell damage
[Corresponding function]
-Identification of failed solar cell module-Identification
of failed solar cell module failure Cluster identification
-Failed sun Identification of failed cells in the battery module
・ Open failure detection of bypass diodes in the cluster
The string output is low.
* The series electric circuit in the module is partially damaged.
(1) Partial disconnection of the interconnector of the solar cell
(2) Damage to the cell of the solar cell
[Corresponding function]
-Identification of the failed solar cell module-Identification
of the failed solar cell module-Identification of the failed cluster-
Failed cell of the failed solar cell
Detecting open failure of bypass diode in specific / cluster
Specifications of cell line checker SPLC-A (failure module identification device)
Applicable voltage range | DC0-1000V |
---|---|
Signal method | [Signal current generation for magnetic field] High-frequency constant current consumption method by direct regulation |
Signal current | 50mAp-p (square wave) |
Signal frequency | [Signal current for magnetic field] 5kHz |
Minimum operating voltage | DC20V (50mAp-p constant current operation start voltage) |
Operating voltage display | Blinking at DC20V or higher |
Built-in sensor | Magnetic field detection sensor x 1 |
External sensor (rod sensor) | Magnetic field detection sensor x 2 |
Power supply | 9V battery x 1 (manganese or alkali) |
Auto power off | Automatically turns off 10 minutes after no operation or reception |