Measurement Range*
|
0 ~ 100% RH
0 ~ 100℃ (-20 ~ +80℃, 0 ~ 50℃, -40 ~ +60℃ available)
|
Accuracy (At 25℃ )
|
±2 % RH, ±0.3℃ (※Power supply = 24VDC)
|
Long-Term Stability
|
Better than 1.5% RH per year (Typical)
|
Temp. Compensation
|
± 0.008% RH /℃ (Effect @ 0 % RH)
|
Response
|
<30 sec. (90 % at +25℃ in moving air over 0.5 M/S)
|
Sensors
|
Humidity : Thin-film capacitor
Temperature : RTD Pt 100Ω IEC 751, DIN43760
|
Output*
|
Current output : Humidity : 4 ~ 20 mA Two wire
Temperature : 4 ~ 20 mA Two wire
Voltage output : 0 to 1V, 0 to 5V, 0 to 10V or 1 to 5V, Selectable
※Other scales possible upon request
|
Fine adjustment
|
Zero and Span adjustable by spare potentiometer
|
Power Supply
|
12 ~ 40VDC, >150mA, Recommended DC24V
|
Housing / Protection
|
Outdoor used Applications, Bears the climate and preventing radiant heat
|
Internal Transmitter
|
IP65 rated, ABS plastic watertight enclosure
|
Cable gland
|
Liquid-tight nylon, cable Bushing: ø5-10mm
|
Ambient Temperature
|
-40 ~ +60℃ (- 40 ~ +140℉)
|
Dimensions
|
210 (L) × 185 (W) × 210 (H) mm
|
Weight
|
Approx. 1500g ※Bracket fixing exception
|
Mounting
|
Complete set with galvanized steel mounting hardware
|
Approvals
|
IP65, CE, RoHS
|