SRA20-D2 albedometer is an instrument that measures global and reflected solar radiation and the solar albedo, or solar reflectance, with the highest accuracy. It is composed of two SR20-D2 secondary standard pyranometers, one sun screen, one glare screen and one fixture with rod. Mounting hardware and tools are included. Each pyranometer offers two types of commonly used irradiance outputs: digital via Modbus RTU over RS-485 and analogue 4-20 mA (current loop). Individually tested for temperature and directional response, SRA20-D2 is the most accurate digital secondary standard albedometer available. SRA20-D2 complies with the latest ISO and WMO standards. The modular design facilitates maintenance and calibration.
|
Measurand |
global solar radiation and reflected solar radiation |
|
Measurement range |
0 to 2000 W/m² |
|
Optional measurand |
albedo or solar reflectance ,net solar radiation |
|
Included sensors |
2 x identical ISO 9060 secondary standard pyranometer |
|
Mounting |
mounting rod with 15 x 10⁻³ m diameter |
|
Calibration uncertainty |
< 1.2 % (k = 2) |
|
Calibration traceability |
to WRR |
|
Spectral range |
285 to 3000 x 10⁻⁹ m |
|
Rated operating temperature range |
-40 to +80 °C |
|
Temperature response |
< ± 0.4 % (-30 to +50 °C) |
|
Temperature response test and directional response test of individual instrument |
Reports included |
|
Standard cable length |
2 x 5 m (see options) |
|
Communication protocol |
Modbus over 2-wire RS-485 |
|
Transmission mode |
RTU |
|
Rated operating voltage |
5 to 30 VDC range |
|
Power consumption |
< 150 x 10⁻³ W at 12 VDC (in total) |
|
Output |
irradiance in W/m² |
|
Transmitted range of 4-20 mA output |
0 to 1600 W/m² |
|
Rated operating voltage of 4-20 mA output |
5.5 to 40 VDC range |
|
- main supply |
< 150 x 10⁻³ W at 12 VDC (in total) |
|
- 4-20 mA current loop |
< 80 x 10⁻³ W at 12 VDC, with recommended 2 x 100 Ω shunt resistors |
|
Sensors |
(2 x) SR20-D2 secondary standard pyranometer |
|
Included with AMF02 |
(1 x) glare screen; (1 x) fixture with rod; (2 x) o-ring; (1 x) conical positioner); (2 x) plug (pre-mounted); (2 x) M5x12 socket head cap screw; (1 x) M6x10 socket head cap screw; (2 x) M6x12 set screw (pre-mounted); (1 x) instruction sheet |