Insulation Resistance Tester
The TOS7200 is an insulation resistance tester available for a wide range of various electric and electronic components, as well as electric and electronic equipment. Output voltage can be optionally set in the range of -25 to -1000 Vdc with a resolution of 1 V. As it is fitted with a window comparator and timer function, the tester is capable of efficiently conducting insulation resistance tests based on various safety standards. In addition, this product is equipped with panel memory as standard feature, which can be recalled by remote control, SIGNAL I/O connector, and the RS-232C interface for easy automatic testing system construction.
TOS7200 SPECIFICATIONS |
|
Model |
|
OUTPUT SECTION |
|
Output voltage range |
-25 V to -1000 V |
Resolution |
1 V |
Accuracy |
±(1.5 % of setting + 2 V) |
Maximum rated load |
1 W (1 000 V/1 mA) |
Maximum rated current |
1 mA |
Output terminals |
|
Output type |
Floating |
Isolation voltage |
±1000 VDC |
Ripple |
|
1000 V / under no load |
2 Vp-p or less |
Maximum rated load |
10 Vp-p or less |
Short-circuiting current |
12 mA or less |
Output rise time |
50 ms or less (10 % to 90 %) [no load] |
Discharge function |
Forced discharge at the end of test (discharge resistance: 25 kΩ) |
VOLTMETER |
|
Measurement range |
0 V to -1200 V |
Resolution |
1 V |
Accuracy |
±(1 % of reading +1 V) |
RESISTANCE METER |
|
Measurement range |
0.01 MΩ to 5000 MΩ (In the range of over 100 nA to a maximum rated current of 1 mA) |
Display |
R < 10.0 MΩ – 10.0MΩ ≤ R < 100.0MΩ – 100.0MΩ ≤ R < 1000MΩ – 1000MΩ ≤ R ≤ 5000MΩ □.□□ MΩ – □□.□ MΩ – □□□ MΩ – □□□□ MΩ |
Accuracy |
100 nA < i ≤ 200 nA, 200 nA < i ≤ 1 µA, 1 µA < i ≤ 1 mA ± (10 % of reading), ± (5 % of reading), ± (2 % of reading) [In the humidity range of 20 %rh to 70 %rh (no condensation), with no disturbance such as swinging of the test leadwire] |
Measurement range |
The current measurement range is selectable between AUTO and FIX. |
AUTO |
Automatically changes the current measurement range according to the measured current value. |
FIX |
Fixes the current measurement range based on the output voltage set value and LOWER set value (in UPPER OFF status). |
Holding function |
Holds the resistance value obtained at the end of testing while a PASS judgment is being output. |
ENVIRONMENT |
|
Installation location |
Indoors and at altitudes up to 2000 m |
Warranty range |
Temperature: 5 °C to 35 °C Humidity: 20 %rh to 80 %rh (no condensation) |
Operating range |
Temperature: 0 °C to 40 °C Humidity: 20 %rh to 80 %rh (no condensation) |
Storage range |
Temperature: -20 °C to 70 °C Humidity: 90 %rh or less (no condensation) |
POWER REQUIREMENTS |
|
Nominal voltage range (allowable voltage range) |
100 V to 240 V AC (85 V to 250 V AC) |
Power consumption at rated load |
30 VA maximum |
Allowable frequency range |
47 Hz to 63 Hz |
Insulation resistance |
30 MΩ or more (500 V DC) [AC LINE to chassis] |
Hipot |
1390 V AC for 2 seconds, 10 mA or less [AC LINE to chassis] |
Ground bond |
25 A AC / 0.1 Ω or less |