รหัสสินค้า | SKU-15390 |
หมวดหมู่ | เครื่องจ่ายไฟกระแสตรง(DC Power Supply) |
ราคาปกติ | |
ลดเหลือ | 0.00 บาท |
สถานะสินค้า | Pre-Order |
สภาพ | สินค้าใหม่ |
ลงสินค้า | 17 มิ.ย. 2566 |
อัพเดทล่าสุด | 26 มิ.ย. 2567 |
คงเหลือ | 1 ชิ้น |
จำนวน | ชิ้น |
The PWR-01 (Zero One) series is a compact, high-performance, multi-functional compact wide-range DC power supply.
There are 16 models, 4 types (L, ML, MH, H) with maximum output voltage and 4 models (400W, 800W, 1200W, 2000W) with maximum output power. In addition, this product can automatically control the output using the sequence function. A computer is required to edit the program, but once the program is written to the power supply (memory), the sequence can be executed simply by operating the panel. Furthermore, LAN (LXI), USB, and RS232C are installed as standard communication interfaces that are indispensable for system upgrades.
In addition, it is equipped with practical and convenient functions as a benchtop DC power supply, such as a front output terminal, internal resistance variable function, bleeder ON/OFF function, CV/CC priority switching function, synchronous operation function, various protection functions, and memory function. increase.
name |
Compact wide range DC power supply PWR-01 series |
|
Model |
PWR2001L |
|
Basic function |
Direct current power supply (DC) output from commercial power supply (AC100V, 200V) |
|
output |
||
Rating |
output power |
2000.0W |
output voltage |
40.00V |
|
output current |
200.00A |
|
Voltage |
Maximum voltage that can be set |
42V |
Setting accuracy |
± (0.05% of set + 0.05% of rating) |
|
Setting resolution |
200mV |
|
10mV (when FINE applied OUTOFF), 1mV (when FINE applied OUTON), 1mV (when using communication interface) |
||
Power fluctuation |
±6mV |
|
load change |
±6mV |
|
transient response |
1 ms or less |
|
ripple noise |
50mVp-p, 5mV (rms/measurement frequency band is 10Hz to 1MHz) |
|
rise time |
50 ms or less (full load, no load) |
|
fall time |
50ms or less (full load), 500ms or less (no load) |
|
Remote sensing |
1.5V |
|
temperature coefficient |
100ppm/°C (in the range of ambient temperature 0°C to 50°C) |
|
current |
Settable maximum current |
210A |
Setting accuracy |
± (0.5% of set + 0.1% of rating) |
|
Setting resolution |
1000mA |
|
100mA (FINE/OUTOFF) |
||
10mA (FINE/OUTON) |
||
0.1mA (when using communication interface) |
||
Power fluctuation |
±22mA |
|
load change |
±45mA |
|
Ripple noise (rms) |
400mA |
|
rise time |
50ms (full load) |
|
fall time |
50ms (full load) |
|
current temperature coefficient |
100ppm/℃ |
|
Maximum settable internal resistance |
0.200Ω |
|
Display function |
||
voltage display |
Maximum display |
99.99 |
Display accuracy |
±(0.2% of reading +5 digits) |
|
current display |
Maximum display |
999.9 |
Display accuracy |
±(0.5% of reading +8 digits) |
|
power display |
Maximum display |
9999 |
Display accuracy |
Switch the display between the multiplication result of the current value and the voltage value |
|
PWR DSPL key lit (red) |
||
AC input |
||
Nominal input rating |
100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase |
|
Input voltage range |
85Vac to 265Vac |
|
Input frequency range |
47Hz to 63Hz |
|
Current |
100Vac |
28.0A |
200Vac |
14.0A |
|
Inrush current (MAX) |
125A or less |
|
Power (MAX) |
2800VA |
|
Power factor (TYP value) |
0.99 (input voltage 100 V) / 0.97 (input voltage 200 V) |
|
Efficiency (MIN) |
75% typ. |
|
Power failure holding time (MIN) |
20 ms or more |
|
protective function |
||
Overvoltage protection (OVP) |
Output off, OVP display, ALM lighting |
|
Setting range: 10% to 112% of rated output, setting accuracy: ±(1.5% of rating) |
||
Overcurrent protection (OCP) |
Output off, OCP display, ALM lighting |
|
10% to 112% of rated output |
||
Front output terminal overcurrent protection |
Output off, OCP display, ALM lighting |
|
11A (TYP value) |
||
Constant voltage limit (UVL) |
Output off, OCP display, ALM lighting |
|
Setting range: 0% to 105% of rated output voltage |
||
Overheat protection (OHP) |
Output off, OHP display, ALM lighting |
|
Sensing Incorrect Connection Protection |
Output off, SENS display, ALM lighting |
|
Low AC input protection |
Output off, AC indication, ALM lighting |
|
Shutdown (SD) |
Output off, SD display, ALM lighting |
|
POWER LIMIT |
ALM lighting, set value (fixed): about 105% of rated output power |
|
Communication monitoring (WATCHDOG) |
Output off, WDOG display, ALM lighting |
|
Master-slave parallel operation protection |
Output off, PRL display, ALM lighting |
|
Signal output/input |
||
Monitor |
Voltage monitor |
Selectable monitor voltage range: 0V to 5V or 0V to 10V |
Setting accuracy: 2.5% of fs |
||
Current monitor |
Selectable monitor voltage range: 0V to 5V or 0V to 10V |
|
Setting accuracy: 2.5% of fs |
||
Status |
OUT ON STATUS |
On when output is on |
|
CV STATUS |
ON during CV operation |
CC STATUS |
On during CC operation |
|
ALARM STATUS |
ON when alarm is activated |
|
POWER ON STATUS |
On when POWER is on |
|
trigger |
Input (TRG IN) |
Logic selectable: LOW (0V to 1.5V), HGH (3.5V to 5V) / Input impedance: 10kΩ (TYP value) |
Output (TRG OUT) |
Logic selectable: LOW (0V to 0.6V), HGH (4.2V to 5V) / Pulse width: 100μs (TYP value) |
|
Control function (external control) |
||
Output voltage control (VPGM) |
0% to 100% of rated output voltage, selectable control voltage: 0V to 5V, or 0V to 10V |
|
Output current control (IPGM) |
0% to 100% of rated output current, selectable control voltage: 0V to 5V, or 0V to 10V |
|
Output ON/OFF control OUTPUT ON/OFF CONT |
Logic selectable: |
|
Output shutdown control |
LOW (0V to 0.5V) or short circuit output off |
|
Alarm clear control ALM CLR |
Alarm clear on LOW (0V to 0.5V) or short circuit |
|
Other features |
||
Output on/off delay |
Setting range: 0.0 s, 0.5 s to 99.9 s (factory setting: 0.0 s) Setting resolution: 0.1 s |
|
Soft start/soft stop |
Setting range: 0.0 s, 0.5 s to 10.0 s (factory setting: 0.0 s) Setting resolution: 0.1 s |
|
Overcurrent protection (OCP) |
Setting range: 0.0 s to 2.0 s (factory setting: 0.0 s) Setting resolution: 0.1 s |
|
preset memory |
Saves up to three combinations of voltage settings, current settings, OVP settings, OCP settings, and UVL settings |
|
key lock |
Disable operations other than the OUTPUT key |
|
config shortcut |
Register up to three config setting items to the SC1, SC2, and SC3 keys |
|
sequence |
Number of programs: 1 Number of steps: 64 |
|
Synchronous operation |
Synchronize voltage and current settings, synchronize step restart of sequence program |
|
One-control parallel operation |
Up to 2 units including the master unit (same model) |
|
Series operation |
2 units (same model) |
|
Multi- |
Connection between master unit and PC |
LAN, USB, RS232C |
Slave unit connection |
LANs |
|
Operation display |
||
OUTPUT ON/OFF |
OUTPUT LED lights (green) when output is on |
|
Output on/off delay |
”DLY” lights when setting, ”DLY” blinks during operation |
|
Soft start/ soft stop |
”SS” lights when setting, ”SS” blinks during operation |
|
CV operation |
CV LED lights (green) |
|
CC operation |
CC LED lit (red) |
|
alarm action |
ALM LED lights up (red) when protection function is activated |
|
preset memory |
One of the PRESET A/B/C LEDs lights up (green) when recalling/saving preset memory |
|
key lock operation |
LOCK LED lights up (green) when keys are locked |
|
remote operation |
REMOTE LED lit (green) during remote control |
|
remote |
LAN operation |
LAN LED Lighting/blinking (changes depending on the state) |
bleeder circuit |
”HB” lights when hyper bleeder is set |
|
Variable internal resistance (VIR) |
”VIR” lights when setting |
|
sequence |
”SEQ” lights while sequence is running, ”SEQ” blinks while waiting for trigger |
|
interface |
||
Common specifications |
Software |
IEEE Std 488.2-1992 |
command language |
Conforms to SCPI Specification 1999.0 |
|
RS232C |
hardware |
Conforms to EIA232D specifications (excluding connectors) |
RJ-45 connector [male] (conversion cable RD-8P/9P is optional) |
||
Baud rate : 1 200, 2 400, 4800, 9600, 19200, 38400, 57 600, 115200 bps |
||
Data length 8 bits, stop bit 1 bit, no parity bit |
||
no flow control |
||
program message terminator |
LF when receiving, CR/LF when sending |
|
USB |
hardware |
Conforms to IEEE 802.3 100Base-TX/10Base-T Ethernet LXI Specification 2011 Ver.1.4 |
IPv4, RJ-45 connector (Category 5, uses straight cable) |
||
program message terminator |
LF or EOM for reception, LF + EOM for transmission |
|
device class |
Compliant with USBTMC-USB488 Device Class Specification |
|
LANs |
hardware |
Conforms to IEEE 802.3 100Base-TX/10Base-T Ethernet LXI Specification 2011 Ver.1.4 |
IPv4, RJ-45 connector (Category 5, uses straight cable) |
||
Communication protocol |
VXI-11, SCPI-RAW, HiSLIP |
|
program message terminator |
VXI-11, HiSLIP: LF or END when receiving, LF + END when sending SCPI-RAW: LF when receiving, LF when sending |
|
General |
||
Mass (body only) |
about 13 kg |
|
Dimensions (WxTxD) |
450×153×420mm |
|
Environmental condition |
Operating environment |
Operating environment |
operating temperature |
operating temperature |
|
operating humidity |
20 %rh to 85 %rh (non-condensing) |
|
storage temperature |
-10°C to +60°C |
|
storage humidity |
90 %rh or less (no condensation) |
|
Altitude |
Up to 2000m |
|
cooling method |
Forced air cooling by fan |
|
ground polarity |
Can be grounded negatively or positively |
|
isolation voltage |
L/ML/MH type: ±500 Vmax, H type: ±800 Vmax |
|
Withstand voltage |
Primary — Between Chassis |
No abnormality after applying 1500 Vac for 1 minute |
primary to secondary |
L / ML / MH type: 1650 Vac applied for 1 minute, no abnormality |
|
Secondary — inter-chassis |
L / ML / MH type: 2300 Vdc, no abnormalities after 1 minute |
|
insulation resistance |
Primary — Between Chassis |
500 Vdc, 100 MΩ or more (70% or less) |
primary to secondary |
L / ML / MH type: 500 Vdc, 100 MΩ or more (70 % or less) |
|
Secondary — inter-chassis |
L / ML / MH type: 500 Vdc, 40 MΩ or more (70 % or less) |
|
accessories |
Instruction manual, short bar for chassis connection, M4 screw for output terminal, OUTPUT terminal cover, |
|
Electromagnetic Compatibility (EMC) |
Conforms to the requirements of the following directives and standards |
|
safety |
Conforms to the requirements of the following directives and standards |