· Output voltage: 10 types from 6V to 600V
· Compact, lightweight, high-efficiency switching method
· Variable output slew rate function
· Equipped with internal resistance control function
· Remote sensing
· Control / monitoring from an internet browser
· 3-point preset memory
· Test mode (sequence)
· Equipped with CC priority mode
· Parallel connection of up to 4 units
· 1U size / 19 inch rack mount compatible
· LAN, RS-232C / RS-485, USB standard equipment
· Supports GP-IB as a factory option
· Worldwide compatible AC input
· RoHS / CE directive compliant
· Log acquisition is possible every 0.1 seconds with the logging option

6V, 12.5V, 20V, 40, 60V models
|
Output rating |
|||||||
|
Model name |
PSU |
6-200 |
12.5-120 |
20-76 |
40-38 |
60-25 |
|
|
Rated output voltage (* 1) |
[V] |
6 |
12.5 |
20 |
40 |
60 |
|
|
Rated output current (* 2) |
[A] |
200 |
120 |
76 76 |
38 |
25 |
|
|
Rated output power |
[W] |
1200 |
1500 |
1520 |
1520 |
1500 |
|
|
Constant voltage characteristics |
|||||||
|
Model name |
PSU |
6-200 |
12.5-120 |
20-76 |
40-38 |
60-25 |
|
|
Input fluctuation (* 3) |
mV |
2.6 2.6 |
3.25 |
4 |
6 |
8 |
|
|
Load fluctuation (* 4) |
mV |
2.6 2.6 |
3.25 |
4 |
6 |
8 |
|
|
Ripple noise (* 5) |
pp (* 6) |
mV |
60 |
60 |
60 |
60 |
60 |
|
rms (* 7) |
mV |
8 |
8 |
8 |
8 |
8 |
|
|
Temperature coefficient |
100ppm / ° C (after warming up for 30 minutes or more) |
||||||
|
Remote sensing compensation |
(One side) |
V |
1 |
1 |
1 |
2 |
3 |
|
Rise time (* 8) |
Full load |
ms |
80 |
80 |
80 |
80 |
80 |
|
No load |
ms |
80 |
80 |
80 |
80 |
80 |
|
|
Falling time (* 9) |
Full load |
ms |
Ten |
50 |
50 |
80 |
80 |
|
No load |
ms |
500 |
700 700 |
800 |
1000 |
1100 |
|
|
Transient response time (* 10) |
ms |
1.5 1.5 |
1 |
1 |
1 |
1 |
|
|
Constant current characteristics |
|||||||
|
Model name |
PSU |
6-200 |
12.5-120 |
20-76 |
40-38 |
60-25 |
|
|
Input fluctuation (* 3) |
mA |
25 |
14 |
9.6 |
5.8 |
4.5 4.5 |
|
|
Load fluctuation (* 11) |
mA |
45 45 |
29 |
20.2 |
12.6 |
10 |
|
|
Ripple noise (* 5) |
rms |
mA |
400 |
240 |
152 |
95 |
75 |
|
Temperature coefficient |
100ppm / ° C (after warming up for 30 minutes or more) |
||||||
|
Protection function |
|||||||
|
Model name |
PSU |
6-200 |
12.5-120 |
20-76 |
40-38 |
60-25 |
|
|
Overvoltage protection (OVP) |
Setting range |
V |
0.6 ~ 6.6 |
1.25 ~ 13.75 |
2 ~ 22 |
4 ~ 44 |
5 ~ 66 |
|
resolution |
V |
0.06 |
0.125 |
0.2 0.2 |
0.4 0.4 |
0.6 |
|
|
Overcurrent protection (OCP) |
Setting range |
A |
5 ~ 220 |
5 ~ 132 |
5 ~ 83.6 |
3.8 ~ 41.8 |
2.5 ~ 27.5 |
|
resolution |
A |
4 |
2.4 |
1.52 |
0.76 |
0.5 |
|
|
Heat protection (OHP) |
Protective operation: Output off |
||||||
|
Sensing (SENSE) |
Protective operation: Output off |
||||||
|
Input protection (AC-FAIL) |
Protective operation: Output off |
||||||
|
Shutdown (SD) |
Protective operation: Output off |
||||||
|
Overpower protection (OPL) |
Protective operation: Output is turned off when the rated power exceeds 105% |
||||||
|
External analog control |
|||||||
|
Model name |
PSU |
6-200 |
12.5-120 |
20-76 |
40-38 |
60-25 |
|
|
Output voltage control by external voltage |
0% to 100% of the rated voltage (0V to 5V / 0V to 10V) |
||||||
|
Output current control by external voltage |
0% to 100% of rated current (0V to 5V / 0V to 10V) |
||||||
|
Output voltage control by external resistance |
0% to 100% of the rated voltage (0kΩ to 5kΩ / 0kΩ to 10kΩ) |
||||||
|
Output current control by external resistance |
0% to 100% of rated current (0kΩ to 5kΩ / 0kΩ to 10kΩ) |
||||||
|
Output voltage monitor |
Monitor voltage selectable: 0V ~ 5V or 0V ~ 10V, accuracy 1% |
||||||
|
Output current monitor |
Monitor voltage selectable: 0V ~ 5V or 0V ~ 10V, accuracy 1% |
||||||
|
Shutdown input |
Output off due to TTL L level (0 to 0.5V) or short circuit |
||||||
|
Output on / off input |
Positive logic / negative logic selectable: Output ON / OFF by TTL or short circuit open |
||||||
|
Alarm clear input |
Clear alarm by inputting TTL L level (0 ~ 0.5V) |
||||||
|
Status output CV / CC / ALM / PWR ON / OUT ON |
Open collector output, external power supply up to 30V, maximum sink current 8mA |
||||||
|
Trigger output |
TTL output, L level output: maximum 0.8V, H level output: minimum 2.0V, maximum sink current 8mA |
||||||
|
Trigger input |
TTL input, L level input: maximum 0.8V, H level input: minimum 2.0V, maximum sink current 8mA |
||||||
|
front panel |
|||||||
|
Model name |
PSU |
6-200 |
12.5-120 |
20-76 |
40-38 |
60-25 |
|
|
7-segment display |
|||||||
|
Voltage accuracy |
0.1% + |
mV |
12 |
25 |
40 |
80 |
120 |
|
Current accuracy |
0.2% + |
mA |
600 |
360 |
228 |
114 114 |
75 |
|
display |
Green LED: CV, CC, V, A, VSR, ISR, DLY, RMT, LAN, M1, M2, M3, RUN, Output ON, |
||||||
|
button |
Button Lock / Local (Unlock), PROT (ALM_CLR), Function (M1), Test (M2), Set (M3), Shift, Output |
||||||
|
encoder |
Voltage setting, current setting |
||||||
|
USB port |
Type A |
||||||
|
Digital control (RS-232 / 485, USB, LAN, GP-IB) |
|||||||
|
Model name |
PSU |
6-200 |
12.5-120 |
20-76 |
40-38 |
60-25 |
|
|
Output voltage accuracy |
0.05% + |
mV |
3 |
6.25 |
10 |
20 |
30 |
|
Output current accuracy |
0.2% + |
mA |
200 |
120 |
76 76 |
38 |
25 |
|
Voltage setting resolution |
mV |
0.2 0.2 |
0.4 0.4 |
0.7 |
1.3 1.3 |
2 |
|
|
Current setting resolution |
mA |
6 |
4 |
2.5 |
1.2 1.2 |
0.8 0.8 |
|
|
Voltage measurement accuracy |
0.1% + |
mV |
6 |
12.5 |
20 |
40 |
60 |
|
Current measurement accuracy |
0.2% + |
mA |
400 |
240 |
152 |
76 76 |
50 |
|
Voltage measurement resolution |
mV |
0.2 0.2 |
0.4 0.4 |
0.7 |
1.3 1.3 |
2 |
|
|
Current measurement resolution |
mA |
6 |
4 |
2.5 |
1.2 1.2 |
0.8 0.8 |
|
|
Input characteristics |
|||||||
|
Model name |
PSU |
6-200 |
12.5-120 |
20-76 |
40-38 |
60-25 |
|
|
Input rating |
100Vac ~ 240Vac, 50Hz ~ 60Hz, single phase, AC cable is not included. |
||||||
|
Input range |
85Vac ~ 265Vac, 47Hz ~ 63Hz |
||||||
|
Maximum input current |
21A (100Vac), 11A (200Vac) |
||||||
|
Inrush current |
50A or less |
||||||
|
power consumption |
2000VA |
||||||
|
Power factor |
0.99 (100Vac), 0.98 (200Vac) |
||||||
|
Efficiency (* 13) |
100Vac |
%% |
77 77 |
82 |
83 |
84 84 |
84 84 |
|
200Vac |
%% |
79 79 |
85 |
86 |
87 |
87 |
|
|
Retention time |
20ms or more |
||||||
|
Interface |
|||||||
|
Model name |
PSU |
6-200 |
12.5-120 |
20-76 |
40-38 |
60-25 |
|
|
USB |
TypeA front, Mass storage class for USB memory |
||||||
|
LAN |
RJ-45, 10 / 100Mbps (IEEE802.3), MAC address, DNS address, password, |
||||||
|
GP-IB |
IEEE 488. 1 compliant |
||||||
|
RS-232C |
EIA-232D compliant |
||||||
|
RS-485 |
EIA-485 compliant |
||||||
|
command |
SCPI-1993, IEEE 488.2 compliant |
||||||
|
Environmental condition |
|||||||
|
Model name |
PSU |
6-200 |
12.5-120 |
20-76 |
40-38 |
60-25 |
|
|
Operating temperature |
0 ℃ to 50 ℃ |
||||||
|
storage temperature |
-25 ℃ to 70 ℃ |
||||||
|
Operating humidity |
20% to 85% RH; (without condensation) |
||||||
|
Storage humidity |
90% RH or less; (without condensation) |
||||||
|
Altitude |
Up to 2000m |
||||||
|
General specifications |
|||||||
|
Model name |
PSU |
6-200 |
12.5-120 |
20-76 |
40-38 |
60-25 |
|
|
mass |
8.7kg or less |
||||||
|
Size |
423.0 x 43.6 x 447.2 mm (W x H x D) |
||||||
|
cooling method |
Forced air cooling |
||||||
|
Withstand voltage |
AC-between chassis: 1500Vac / 1 minute, AC-output: 3000Vac / 1 minute |
||||||
|
Insulation resistance |
100MΩ or more (DC 500V) |
||||||
|
accessories |
CD-ROM (Instruction manual, output terminal cover, analog connector kit, |
||||||
(* 1) The minimum voltage is 0.2% of the rated output voltage.
(* 2) The minimum current is 0.4% of the rated current output.
(* 3) AC85V ~ AC132V or AC170V ~ AC 265V, with fixed load
(* 4) No load to full load, AC input voltage constant, when using remote sensing
(* 5) JEITA RC-9131B (1: 1) probe (
* 6) 20MHz band-limited filter used
(* 7) 5Hz ~ 1MHz bandpass filter used
(* 8) Time from 10% to 90% of rated voltage, resistance load
(* 9) 90% of rated voltage It is the time from 10% to 10%, and the time when the
output voltage recovers within 0.5% of the rated voltage under the resistance load (* 10). Fluctuations in load current range from 10% to 90% of the rating. The fluctuation of the output voltage is 10% to 100% of the rating
(* 11) When the output voltage is variable (between 0 and rated voltage), when the input voltage is constant
(* 12) The output voltage of the 6V model is 2V to 6V (when the rated current). ) Value. For other models, the output voltage is rated from 10% to 100% (at rated current).
(* 13) Input voltage AC100V / AC200V, rated output power












Realtools Asia(ศูนย์รวมเครื่องมือวัดและชุดทดสอบอุตสาหกรรม)