Target gas: Oxygen (diaphragm galvanic cell system) issue of calibration document
Measurement range: 0 to 25.0 vol.%
Alarm set value: 1st stage 19.5 vol.%, 2nd stage 18.0 vol.%
product name | Price (tax included) | |
---|---|---|
Oxygen meter XO-2200 [New Cosmos Electric] |
Target gas: Oxygen and carbon monoxide Oxygen range: 0 to 25.0 vol.% CO range: 0 to 300 ppm Issuable of calibration documents
O2 alarm set value: 1st stage 19.5 vol.%, 2nd stage 18.0 vol.%
CO alert Setting value: 1st stage 50 ppm, 2nd stage 150 ppm
product name | Price (tax included) | |
---|---|---|
Oxygen and carbon monoxide analyzer XOC-2200 [New Cosmos Electric] |
Target gas: oxygen detection range: 0 to 40.0 vol% Intrinsically safe explosion-proof structure Issuable of ExiaTIIC 4X calibration document
L alarm 19.5 vol% LL alarm 18.0 vol% OVER 40.0 vol%
alkaline dry battery × 2 pieces: about 3000 hours OX-01 Successor model
product name | Price (tax included) | |
---|---|---|
RIKEN Pocketable Oxygen Monitor OX-03 * Battery specification | ||
RIKEN Pocketable Oxygen Monitor OX-03 * Battery specification |
Pocket-sized carbon monoxide monitor that protects workers. Visibility at the time of warning is improved by the color liquid crystal display adoption which can issue the proofreading document
. -Gas to be
detected: oxygen (galvanic cell type) , carbon monoxide (constant potential electrolytic type) -Measurement range: oxygen 0 to 25.0 vol.% , Carbon monoxide 0 to 300 ppm
product name | Price (tax included) | |
---|---|---|
Oxygen and carbon monoxide analyzer XOC-353II | ||
Oxygen and carbon monoxide analyzer XOC-353II 3 sets |
Pocket-sized carbon monoxide monitor that protects workers. Visibility at the time of warning is improved by the color liquid crystal display adoption which can issue the proofreading document
.
・ Gas to be detected: Oxygen (galvanic cell type) detection range: 0 to 25 vol% (25.1 to 50.0 vol%)
product name | Price (tax included) | |
---|---|---|
Oxygen concentration meter XO-353II | ||
Oximeter XO-353II 3 sets |
Pocket-sized carbon monoxide monitor that protects workers. Visibility at the time of warning is improved by the color liquid crystal display adoption which can issue the proofreading document
. -Gas to be detected
: oxygen (galvanic cell type) hydrogen sulfide (constant potential electrolytic type) -detectionrange: oxygen 0 to 25 vol% (25.1 to 50.0 vol%) hydrogen sulfide 0 to 30.0 ppm (30.1 to 100.0 ppm)
product name | Price (tax included) | |
---|---|---|
Oxygen and hydrogen sulfide concentration meter XOS-353II | ||
Oxygen and hydrogen sulfide concentration meter XOS-353II 3 sets |
Target gas: Oxygen and hydrogen sulfide Oxygen range: 0 to 25.0 vol.% Hydrogen sulfide: 0 to 30.0 ppm Issuable of calibration documents
O2 alarm set value: 1st stage 19.5 vol.%, 2nd stage 18.0 vol.%
Hydrogen sulfide Alarm setting value: 1st stage 10.0 ppm, 2nd stage 15.0 ppm
product name | Price (tax included) | |
---|---|---|
Oxygen and hydrogen sulfide meter XOS-2200 [New Cosmos Electric] |
Target gas: Oxygen (diaphragm galvanic cell method) Measurement range: 0 to 25.0 vol.% Issuable of calibration documents
JIS T 8201: 2010 Oxygen meter compatible product for measuring oxygen deficiency ● Continuous for about 15000 hours with 2 AA alkaline batteries In the working
tank, in the manhole, underground construction site such as a tunnel, etc. In order to ensure the safety of the working environment and ensure the safety of workers at the bottom of the ship, etc., the warning setting: 1st stage 19.5vol.%, 2 Step 18.0vol.% Alarm with sound and lamp
product name | Price (tax included) | |
---|---|---|
Digital oximeter XO-326IIsA 5m | ||
Digital oximeter XO-326IIsB 1m | ||
Digital oximeter XO-326IIsC 10 m |
Target gas: oxygen and hydrogen sulfide (simultaneous measurement sensor separation type) calibration documents can be issued
5 m sensor cable is standard equipment
Safety in the tank, manhole, tunnel, etc. underground construction site Safety confirmation before work and worker safety To secure.
Oxygen range: 0 to 25.0 vol.% Hydrogen sulfide: 0 to 30.0 ppm
O2 alarm set value: 1st stage 19.5 vol.%, 2nd stage 18.0 vol.% Alarm and
hydrogen sulfide alarm set value with sound and lamp : 1st stage 10.0 ppm, 2nd stage 15.0 ppm
product name | Price (tax included) | |
---|---|---|
Oxygen and hydrogen sulfide meter XOS-326 [New Cosmos Electric] |
!! to lack of oxygen accident prevention of tanks and manhole work TIIS IP67 equivalent oxygen
significantly reduce possible ■ continuous use time is about 20,000 hours and the running cost for the ■ sensor 2 years manufacturer guarantee (about 2 years). ■ Dust-proof and waterproof structure (equivalent to protection grade IP67) including sensors.
product name | Price (tax included) | |
---|---|---|
Injection type portable oxygen monitor OX-08 [Riken Keiki] |
Target gas: Oxygen Measurement range: 0-25 vol% suction type Alarm setting value: 18.0 vol% Issuance of calibration document
Measurement concentration display of 2 patterns with digital bar graph and digital number.
Notification of alarm with buzzer and lamp. Small size, light weight and easy to operate while holding in your hand. 4 AA alkaline batteries Intrinsically safe construction (Exib II BT3) Japan Maritime Association (NK) type approved product No. 06 T 606 (specified required)
product name | Price (tax included) | |
---|---|---|
Oximeter XP-3180 |
-Simultaneous detection and display of low concentration flammable gas and oxygen simultaneously with one unit. Calibration document can be issued
· XP-3118: 0 to 10/0 to 100% LEL combustible gas concentration and oxygen concentration simultaneously measured
· XP-3168: high sensitivity , ppm combustible gas concentration and oxygen concentration simultaneously
Please specify the gas to be measured .
Japan Maritime Association (NK) type approved product No. 06 T 605 (designated required) such as methane, isoptan, propane, ethanol, hydrogen and acetylene
product name | Price (tax included) | |
---|---|---|
Combined gas detector XP-3118 * for specifying oxygen + combustible gas | ||
Combined gas detector XP-3118 * for oxygen + methane gas | ||
Combined gas detector XP-3118 * for oxygen + hydrogen gas | ||
New cost high sensitivity combined gas detector XP-3168 |
Target gas: An oxygen diffusion type alarm is a sound and a lamp, so a large screen that is easy to understand . Voice alarms and backup power supply standard equipment that can issue calibration documents
are highly evaluated by customers.
Detection range : 0 to 25.0 vol% or 0 to 50.0 vol%
Compact, lightweight, single-point oxygen with integrated detection unit and alarm unit Gas detection alarm.
Power supply can be selected from DC / AC / battery (option). Automatic backup enables use of the alarm for more than 2 weeks even at power failure.
product name | Price (tax included) | |
---|---|---|
Oxygen detection alarm KS-7O [new cosmos] |
Lights in green, orange and red 3 colors! Possible to issue an LCD screen calibration documentthat shows the operating status at a glance.-There is
no change in the indicated value due to pressure changes because of the built-in pressure correction sensor.-Three types of power supply specifications selectable according to the operating environment "AC power supply specification" "DC power supply Specifications "dry battery specification"
product name | Price (tax included) | |
---|---|---|
Small oxygen monitor (Integrated type, AC power supply specification) OX-600-00 AC | ||
Compact oxygen monitor (remote sensor 5m · AC power supply specification) OX-600-05AC | ||
Small oxygen monitor (remote sensor 10 m · AC power supply specification) OX-600-10 AC | ||
Small oxygen monitor (Integrated type, dry cell specification) OX-600-00 | ||
Small oxygen monitor (remote sensor 5m, dry cell specification) OX-600-05 | ||
Small oxygen monitor (remote sensor 10m, dry cell specification) OX-600-10 |
Target gas: Oxygen display wall hanging type / detection unit wall hanging type / diffusion type 1 point type installation type oxygen alarm calibration document issueable
gas production and filling establishments, gas consumption facilities, ships and stockpiling bases such as
industrial safety technology association Test pass / JIS M 7653 compliant
option: Analog output 4-20mA , Record data logger function also possible
product name | Price (tax included) | |
---|---|---|
Oxygen alarm TO-303 (TO3W100-DW00) |
Issuance of reliable JIS T8201 2010 calibration documentsOximeter
for measuring oxygen deficiency Measurement
range: 0 to 100% Alarm: Lower limit 18.0 or 19.5% 2 points Optional changeable Portable or installation type OK
Application: Work for preventing an oxygen deficiency For safety applications, management of oxygen concentration in production lines such as factories, and research in various oxygen experiments. Alarm: Electronic buzzer 2 stages, red LED alarm output, analog output as standard
product name | Price (tax included) | |
---|---|---|
Oxygen monitor JKO-25S3 (with sensor) | ||
Oxygen monitor JKO-25L3 (Sensor separation, portable type) | ||
Oxygen monitor JKO-25W3 (Sensor separation and installation type) | ||
Oxygen monitor JKO-25 WD3 (Sensor separation and installation type) | ||
Oxygen monitor JKO-25LJ3 (Sensor separation, inline type) | ||
Oxygen monitor JKO-25LJD3 (Sensor separation, inline type) |
Measurement range: 0 to 100% alarm: Lower limit 18.0 or 19.5% 2 points Optional changeable Calibration document can be issued
Alarm ON / OFF is possible Portable or installed type
: OK Application: Prevention of oxygen deficiency, oxygen concentration management, Oxygen monitor
alarm for various experiments : 2 stages of electronic buzzer, red LED alarm output, analog output as standard
● Alarm output and RS232C output terminal as standard Continuous measurement of 10,000 hours when using dry cell
product name | Price (tax included) | |
---|---|---|
Oxygen monitor OXYMAN OM-25MS-01 (built-in) | ||
Oxygen monitor OXYMAN OM-25MS-10 (separate type) | ||
Oxygen monitor OXYMAN OM-25MF-01 (built-in) | ||
Oxygen monitor OXYMAN OM-25MF-10 (separate type) |
Oxygen Monitor OXYMAN OM-25MF-01 Catalog
It can record 1,500 records. 13 types of sampling intervals 5 seconds to 60 minutes. Issuable
start time of calibration document with reservation function. Possible to set with or without alarm (silence) Power ON / OFF operation possible
Measurement range: 0 to 100% Alarm: Lower limit 18.0 or 19.5% 2 points Optional change is possible Both
portable and installed type are OK. Application: Oxygen deficiency prevention, oxygen concentration control, oxygen monitor
alarm for various experiments : Electronic buzzer 2 stages, red LED alarm output, analog output as standard equipment
● Alarm output and RS232C output terminal as standard equipment ● Continuously 10,000 when dry cell is used Realize time measurement
product name | Price (tax included) | |
---|---|---|
Oxygen monitor logger OXYMAN OM-25MP-01 (built-in) | ||
Oxygen monitor logger OXYMAN OM-25MP-10 (separate type) | ||
Oxygen monitor logger OXYMAN OM-25MP-11 (2ch built-in / separated type) | ||
Oxygen monitor logger OXYMAN OM-25MP-20 (2ch separation type) |
Six component concentration meter of exhaust gas. ※ standard equipped O 2 only
, standard with O 2 in addition to CO (H 2 with compensation) , low concentration CO (H 2 with compensation) , high concentration CO , NO , low concentration NO , NO 2 , SO 2 , CO 2(NDIR) sensors can be mounted. · Combustion adjustment · Combustion adjustment of burners. For research, development and experiments.
product name | Price (tax included) | |
---|---|---|
Combustion exhaust gas analyzer HT-2700 standard set |
Target gas: Oxygen in combustion exhaust gas Issuable of calibration document with calibration Capable of measuring oxygen concentration at high temperature with cooling drain filter Measurement range: 0 to 25.0 vol% Alarm set value: 18.0 vol% Boiler, incinerator etc. For combustion management by measuring oxygen concentration in combustion exhaust gas
product name | Price (tax included) | |
---|---|---|
Combustion management oximeter XP-3180E [New Cosmos Electric] |
Exhaust gas oximeter. Carbon dioxide calculation. For energy saving diagnosis with law revision! Issuance of calibration documents Issuing
boilers,
burners, etc. Oxygen concentration measuring equipment in exhaust gases, etc. ● Measurement items (1) Oxygen concentration (2) Two temperatures (HT-1200NT only)
● Calculation items (1) Carbon dioxide concentration (2) Combustion air ratio (3) Exhaust gas loss (4) Combustion efficiency
product name | Price (tax included) | |
---|---|---|
Combustion exhaust gas analyzer HT-1200N [Hodaka test] | ||
Combustion exhaust gas analyzer HT-1200NT [Hodaka test] with exhaust gas temperature sensor | ||
AC adapter for overseas use AC100-240V | ||
Measurement software for PC HT-2084 (RS232C, USB conversion cable) |
1) Possible to issue calibration document with oxygen concentration (O2)
2) Carbon monoxide concentration (with CO H2 compensation) up to 10,000 ppm
3) Combustion exhaust gas temperature 650 degrees (950 degrees)
product name | Price (tax included) | |
---|---|---|
Combustion exhaust gas analyzer HT-1300NL [Hodaka test] |